Part Number Hot Search : 
1N4148W 16001 10006F 7N50U 960R0 0M000000 ATMEGA64 AC100
Product Description
Full Text Search
 

To Download E32-TC200D4 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Sensing distance
Supply voltage
12 to 24 VDC
Output
100 mA (Optical fiber series)
Optical Fiber Photoelectric Sensor
Leading-edge Features and Long-distance Sensing in an Optical Fiber Photoelectric Sensor
E3X-Tjj with Auto-tuning Function Automatic Sensitivity Adjustment E3X-H11 High-sensitivity Model Senses Distances Twice as Far as those of E3X-Ajj and Performs Detailed Sensing Operations Using the Variable Hysteresis Function E3X-Ajj Standard Model A High-speed Response of 200 s E3X-Fjj High-speed Model Pulse Lighting Mechanism Enables a High-speed Response of 20 s E3X-VGjj Mark Sensor Model Green Light Source Accurately Senses Subtle Differences in Color at a Speed of 200 ms
E3X
Ordering Information
Model Number Legend: E3X 1234
1. Classification T: Auto-tuning H: High-sensitivity A: General-purpose F: Shorter response time V: For mark sensor 2. Light Source None: Red (standard) G: Green 3. Outputs 1: NPN (without self-diagnosis) 2: NPN (with self-diagnosis) 4: PNP (without self-diagnosis) 5: PNP (with self-diagnosis) 4. Output Form 1: Cable
Accessories (Order Separately)
(Cannot be used with the E3X-Tjj.)
1
E3X
Item Application Manual Sensitivity Adjustment Knob Makes adjustment possible without screwdriver. Water-resistance lost when used (enclosure rating reduced to IP50). E39-G3 Protective Cover
E3X
Replacement part for cover supplied with Amplifier Unit. E39-G4
Model Appearance
Amplifier Units
Item Model Appearance
32
Auto-tuning E3X-T11 E3X-T21
High-sensitivity E3X-H11
59 12
Light source Power supply voltage Current consumption Response time Control output Timer function Self-diagnosis alarm output Variable hysteresis function Tuning monitor function Remote tuning function/ Remote bank function
Red LED (660 nm) 12 to 24 VDC +10%, ripple (p-p) 10% max. 50 mA max. 500 ms max. 100 mA max. at 30 VDC, NPN open collector ------Indicator (red/green LED) and buzzer --When ON, short-circuit the blue and pink wires. (Short-circuit the blue and purple wires for remote bank selection.): Short-circuit voltage 3 V max., short-circuit current 5 mA min. When OFF, open the blue and pink wires: 9 V min. (input voltage: 24 V max.), response time 100 ms max. when OFF. OFF-delay timer (fixed to 40 ms), switch selectable 50 mA max. at 30 VDC, open collector --0% to 20% ----10 to 30 VDC +10%, ripple (p-p) 10% max. 35 mA max. 1 m sec max.
Output method
Light ON and Dark ON selector
2
E3X
Item Model Appearance NPN PNP General-purpose E3X-A11 E3X-A41 E3X-A21 E3X-A51 Shorter response time E3X-F21 E3X-F51 --For mark sensing E3X-VG11 E3X-VG21 ---
E3X
Light source Power supply voltage
Red (660 nm) 10 to 30 VDC ripple (p-p) 10% max. 35 mA max. 200 ms max. 12 to 24 VDC +10% ripple (p-p) 10% max. 40 mA max. ON: 20 ms max. OFF: 30 ms max. OFF-delay timer (0.01 to 0.1 s; adjustable), Switch selectable
Green (565 nm) 10 to 30 VDC ripple (p-p) 10% max.
Current consumption Response time Control output Timer function
200 ms max.
100 mA, 30 VDC max., Open collector ----OFF-delay timer (0.01 to 0.1 s; adjustable), Switch selectable 50 mA, 30 VDC max. Residual voltage: 1 VDC max. Light OFF: 1.5 V max; short current: 0.2 mA max. Light ON: Open; 3.5 V min. (max. input: 5 V)
Self-diagnosis alarm output
---
50 mA, 30 VDC max. Residual voltage: 1 VDC max.
---
External diagnosis input
Input voltage
---
Light OFF: NPN: 1.5 V max; short current: 0.2 mA max. PNP: 1.5 V max.; short current: 0.2 mA max. Light ON: NPN: Open; Light OFF: 3.5 V min. (max. input: 5 V) PNP: Open; 3.5 VDC max. (max. input: 5 V) 400 ms 200 ms
---
Response delay
400 ms
3
E3X
Fiber Unit
Through-beam (Separate) Sensors
Model Appearance Sensing distance (standard object)* (T: E3X-Tjj; H: E3X-H11; A: E3X-Ajj; F: E3X-Fjj; V: E3X-VGjj) T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 500 mm (1,200 mm**) (1.4-mm dia. min.) 700 mm (2,000 mm**) (1.4-mm dia. min.) 350 mm (1,000 mm**) (1.4-mm dia. min.) 150 mm (1.4-mm dia. min.) 40 mm (120 mm**) (1.4-mm dia. min.) 500 mm (1.4-mm dia. min.) 700 mm (1.4-mm dia. min.) 350 mm (1.4-mm dia. min.) 150 mm (1.4-mm dia. min.) 40 mm (1.4-mm dia. min.) 150 mm (0.9-mm dia. min.) 200 mm (0.9-mm dia. min.) 100 mm (0.9-mm dia. min.) 50 mm (0.9-mm dia. min.) 10 mm (0.9-mm dia. min.) 150 mm (0.9-mm dia. min.) 200 mm (0.9-mm dia. min.) 100 mm (0.9-mm dia. min.) 50 mm (0.9-mm dia. min.) 10 mm (0.9-mm dia. min.) 270 mm (2,000 mm**) (1-mm dia. min.) 400 mm (3,000 mm**) (1-mm dia. min.) 200 mm (1,500 mm**) (1-mm dia. min.) 80 mm (1-mm dia. min.) 28 mm (190 mm**) (1-mm dia. min.) 270 mm (1-mm dia. min.) 400 mm (1-mm dia. min.) 180 mm (1-mm dia. min.) 80 mm (1-mm dia. min.) 28 mm (1-mm dia. min.) 70 mm (0.5-mm dia. min.) 100 mm (0.5-mm dia. min.) 50 mm (0.5-mm dia. min.) 26 mm (0.5-mm dia. min.) 7 mm (0.5-mm dia. min.) 70 mm (0.5-mm dia. min.) 100 mm (0.5-mm dia. min.) 50 mm (0.5-mm dia. min.) 26 mm (0.5-mm dia. min.) 8 mm (0.5-mm dia. min.) 70 mm (0.5-mm dia. min.) 100 mm (0.5-mm dia. min.) 50 mm (0.5-mm dia. min.) 26 mm (0.5-mm dia. min.) 8 mm (0.5-mm dia. min.) 250 mm (1-mm dia. min.) 360 mm (1-mm dia. min.) 180 mm (1-mm dia. min.) 80 mm (1-mm dia. min.) 28 mm (1-mm dia. min.) 240 mm (1,300 mm**) (1-mm dia. min.) 360 mm (1-mm dia. min.) 180 mm (1,000 mm**) (1-mm dia. min.) 80 mm (1-mm dia. min.) 10 mm (120 mm**) (1-mm dia. min.) 65 mm (0.5-mm dia. min.) 100 mm (0.5-mm dia. min.) 50 mm (0.5-mm dia. min.) 26 mm (0.5-mm dia. min.) 6 mm (0.5-mm dia. min.) Min. sensing object (opaque objects) T: H: A: F: V: T: H: A: F: V: 0.2-mm dia. 0.5-mm dia. 0.5-mm dia. 0.5-mm dia. 0.5-mm dia. 0.2-mm dia. 0.5-mm dia. 0.5-mm dia. 0.5-mm dia. 0.5-mm dia.
E3X
Features
E32-T11L
M4 screw
Long distance
E32-T12L
3-mm dia.
Long distance
E32-T21L
M3 screw
0.2-mm dia.
Long distance with thin fiber
E32-T22L
2-mm dia.
0.2-mm dia.
Long distance with thin fiber
E32-TC200
M4 screw
0.2-mm dia.
General-purpose
E32-TC200B E32-TC200B4
0.2-mm dia.
General-purpose
M4 screw
E32-T22
2-mm dia.
0.2-mm dia.
General-purpose
E32-TC200E
M3 screw
0.2-mm dia.
General-purpose
E32-TC200F E32-TC200F4
0.2-mm dia.
General-purpose
M3 screw
E32-TC200A
M3 screw
T: H: A: F: V: T: H: A: F: V:
0.2-mm dia. 0.3-mm dia. 0.2-mm dia. 0.2-mm dia. 0.2-mm dia. 0.2-mm dia. 0.3-mm dia. 0.2-mm dia. 0.2-mm dia. 0.2-mm dia.
General-purpose
E32-T11
M4 screw
Flexible (resists breaking)
E32-T21
M3 screw
0.2-mm dia.
Flexible (resists breaking)
*Standard object: opaque; **For the E39-F1; ***Not trimmable
4
E3X
Model Appearance Sensing distance (standard object)* (T: E3X-Tjj; H: E3X-H11; A: E3X-Ajj; F: E3X-Fjj; V: E3X-VGjj) T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 200 mm (800 mm**) (1-mm dia. min.) 300 mm (1,600 mm**) (1-mm dia. min.) 150 mm (800 mm**) (1-mm dia. min.) 60 mm (1-mm dia. min.) 18 mm (100 mm) (1-mm dia. min.) 200 mm (1-mm dia. min.) 300 mm (1-mm dia. min.) 150 mm (1-mm dia. min.) 60 mm (1-mm dia. min.) 18 mm (1-mm dia. min.) 130 mm (1-mm dia. min.) 240 mm (1-mm dia. min.) 120 mm (1-mm dia. min.) 30 mm (1-mm dia. min.) 10 mm (1-mm dia. min.) 45 mm (0.5-mm dia. min.) 90 mm (0.5-mm dia. min.) 45 mm (0.5-mm dia. min.) 15 mm (0.5-mm dia. min.) 2 mm (0.5-mm dia. min.) 1,000 mm (4-mm dia. min.) 1,800 mm (4-mm dia. min.) 900 mm (4-mm dia. min.) 380 mm (4-mm dia. min.) 80 mm (4-mm dia. min.) 7,000 mm (10-mm dia. min.) 14,000 mm (10-mm dia. min.) 7,000 mm (10-mm dia. min.) 3,000 mm (10-mm dia. min.) 800 mm (10-mm dia. min.) 1,000 mm (4-mm dia. min.) 1,600 mm (4-mm dia. min.) 800 mm (4-mm dia. min.) 300 mm (4-mm dia. min.) 70 mm (4-mm dia. min.) 200 mm (2-mm dia. min.) 300 mm (2-mm dia. min.) 150 mm (2-mm dia. min.) 65 mm (2-mm dia. min.) 20 mm (2-mm dia. min.) 300 mm (1.5-mm dia. min.) 400 mm (1.5-mm dia. min.) 200 mm (1.5-mm dia. min.) 80 mm (1.5-mm dia. min.) 20 mm (1.5-mm dia. min.) 180 mm (2,000 mm**) (1.0-mm dia. min.) 300 mm (3,000 mm**) (1.0-mm dia. min.) 150 mm (1,500 mm**) (1.0-mm dia. min.) 60 mm (450 mm) (1.0-mm dia. min.) 18 mm (130 mm**) (1.0-mm dia. min.) Min. sensing object (opaque objects) 0.2-mm dia.
E3X
Features
E32-TC200C
M4 screw ****
Flexible spiral cord
E32-TC200D E32-TC200D4
M4 screw ****
0.2-mm dia.
Flexible spiral cord
E32-T14L
3-mm dia.
T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V:
0.3-mm dia. 0.2-mm dia. 0.1-mm dia. 0.2-mm dia. 0.1-mm dia. 0.2-mm dia. 0.1-mm dia. 0.1-mm dia. 0.3-mm dia. 0.2-mm dia. 0.2-mm dia. 1-mm dia. 1-mm dia. 0.2-mm dia. 2-mm dia. 0.7-mm dia. 2.1-mm dia. 0.8-mm dia. 1.5-mm dia. 2.1-mm dia. 0.3-mm dia. 0.7-mm dia. 0.9-mm dia. 0.7-mm dia. 0.6-mm dia. 0.2-mm dia. 0.4-mm dia. 0.3-mm dia. 0.3-mm dia. 0.3-mm dia. 0.4-mm dia. 1.0-mm dia. 1.0-mm dia. 1.0-mm dia. 1.0-mm dia. 0.2-mm dia. 0.3-mm dia. 0.2-mm dia. 0.5-mm dia. 0.5-mm dia.
Side-view; long distance
E32-T24
1-mm dia.
Side-view; save space
E32-T14
Side-view
E32-T17L
M4 screw
Long distance
E32-T12F
5-mm dia.
Teflon-covered*****; withstands chemicals and harsh environments 4-head; 4-point sensing
E32-M21
M3 screw ****
E32-T51
M4 screw
Heat-resistant; resists 150C
E32-T61
M4 screw ****
Heat-resistant; resists 300C
*Standard object: opaque; **For the E39-F1.; ***Sensing distances for slit applications are in the following table. ****Not trimmable *****Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin.
5
E3X
E32-T16 with Slits
Slit width With E3X-Tjj With E3X-H11 With E3X-Ajj With E3X-Fjj With E3X-VGjj Sensing distance Min. sensing object Sensing distance Min. sensing object Sensing distance Min. sensing object Sensing distance Min. sensing object Sensing distance Min. sensing object 450 mm 0.2-mm dia. 900 mm 0.2-mm dia. 450 mm 0.25-mm dia. 120 mm 0.25-mm dia. 20 mm 0.25-mm dia. 0.5-mm 800 mm 0.3-mm dia. 1,200 mm 0.4-mm dia. 600 mm 0.35-mm dia. 250 mm 0.35-mm dia. 60 mm 0.35-mm dia.
Slit Sensing object
E3X
1.0-mm Sensing method
Reflective Sensors
Model Appearance Sensing distance (standard object) (T: E3X-Tjj; H: E3X-H11; A: E3X-Ajj; F: E3X-Fjj; V: E3X-VGjj) White paper E32-D11L
M6 screw
Min. sensing object (copper wire)
Features
Black paper T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 40 mm (20 x 20 cm) 60 mm (20 x 20 cm) 30 mm (10 x 10 cm) 8 mm (5 x 5 cm) --20 mm (10 x 10 cm) 32 mm (20 x 20 cm) 16 mm (10 x 10 cm) 3 mm (2.5 x 2.5 cm) --9 mm (5 x 5 cm) 14 mm (5 x 5 cm) 7 mm (2.5 x 2.5 cm) 2 mm (2.5 x 2.5 cm) --9 mm (5 x 5 cm) 14 mm (5 x 5 cm) 7 mm (2.5 x 2.5 cm) 2 mm (2.5 x 2.5 cm) --20 mm (10 x 10 cm) 30 mm (20 x 20 cm) 15 mm (10 x 10 cm) 5 mm (5 x 5 cm) --20 mm (10 x 10 cm) 30 mm (20 x 20 cm) 15 mm (10 x 10 cm) 5 mm (5 x 5 cm) --4.8 mm (2.5 x 2.5 cm) 7.2 mm (5 x 5 cm) 3.6 mm (2.5 x 2.5 cm) 1.5 mm (2.5 x 2.5 cm) --4.8 mm (2.5 x 2.5 cm) 7.2 mm (5 x 5 cm) 3.6 mm (2.5 x 2.5 cm) 1.5 mm (2.5 x 2.5 cm) --T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 0.015-mm dia. 0.015-mm dia. 0.015-mm dia. 0.2-mm dia. 3.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.04-mm dia. 2.4-mm dia. 1.6-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.26-mm dia. 1.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.26-mm dia. 1.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.015-mm dia. 0.015-mm dia. 0.2-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 0.5-mm dia. Long distance
T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V:
150 mm (20 x 20 cm) 200 mm (20 x 20 cm) 100 mm (10 x 10 cm) 45 mm (5 x 5 cm) 10 mm (2.5 x 2.5 cm) 80 mm (10 x 10 cm) 120 mm (20 x 20 cm) 60 mm (10 x 10 cm) 15 mm (2.5 x 2.5 cm) 2 mm (2.5 x 2.5 cm) 35 mm (5 x 5 cm) 50 mm (5 x 5 cm) 25 mm (2.5 x 2.5 cm) 11 mm (2.5 x 2.5 cm) 1 mm (2.5 x 2.5 cm) 35 mm (5 x 5 cm) 50 mm (5 x 5 cm) 25 mm (2.5 x 2.5 cm) 11 mm (2.5 x 2.5 cm) 1 mm (2.5 x 2.5 cm) 100 mm (10 x 10 cm) 150 mm (20 x 20 cm) 75 mm (10 x 10 cm) 33 mm (5 x 5 cm) 10 mm (2.5 x 2.5 cm) 100 mm (10 x 10 cm) 150 mm (20 x 20 cm) 75 mm (10 x 10 cm) 33 mm (5 x 5 cm) 10 mm (2.5 x 2.5 cm) 20 mm (2.5 x 2.5 cm) 36 mm (5 x 5 cm) 18 mm (2.5 x 2.5 cm) 8 mm (2.5 x 2.5 cm) 2 mm (2.5 x 2.5 cm) 20 mm (2.5 x 2.5 cm) 36 mm (5 x 5 cm) 18 mm (2.5 x 2.5 cm) 8 mm (2.5 x 2.5 cm) 2 mm (2.5 x 2.5 cm)
E32-D12
3 mm dia.
Long distance
E32-D21L
M4 screw
Long distance
E32-D22L
3 mm dia.
Long distance
E32-DC200
M6 screw
General-purpose
E32-DC200B E32-DC200B4
M6 screw
General-purpose
E32-DC200E
M3 screw
General-purpose
E32-DC200F E32-DC200F4
M3 screw
General-purpose
E32-D11
M6 screw
T: 60 mm (10 x 10 cm) H: 90 mm (10 x 10 cm) A: 45 mm (5 x 5 cm) F 20 mm (2.5 x 2.5 cm) V: 7 mm (2.5 x 2.5 cm)
T: 13 mm (10 x 10 cm) H: 20 mm (10 x 10 cm) A: 10 mm (5 x 5 cm) F: 5 mm (2.5 x 2.5 cm) V: ---
Flexible (resists breaking)
6
E3X
Model Appearance Sensing distance (standard object) (T: E3X-Tjj; H: E3X-H11; A: E3X-Ajj; F: E3X-Fjj; V: E3X-VGjj) White paper E32-D21
M3 screw
E3X
Min. sensing object (copper wire) Features
Black paper T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 1.6 mm (2.5 x 2.5 cm) 3 mm (2.5 x 2.5 cm) 1.5 mm (2.5 x 2.5 cm) ----6 mm (5 x 5 cm) 10 mm (5 x 5 cm) 4.5 mm (2.5 x 2.5 cm) ----6 mm (5 x 5 cm) 10 mm (5 x 5 cm) 4.5 mm (2.5 x 2.5 cm) ----T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. Flexible (resists breaking)
T: H: A: F: V: T: H: A: F: V: T: H: A: F: V:
8 mm (2.5 x 2.5 cm) 14 mm (2.5 x 2.5 cm) 7 mm (2.5 x 2.5 cm) 3 mm (2.5 x 2.5 cm) 1 mm (2.5 x 2.5 cm) 30 mm (5 x 5 cm) 44 mm (5 x 5 cm) 22 mm (2.5 x 2.5 cm) 10 mm (2.5 x 2.5 cm) 2.5 mm (2.5 x 2.5 cm) 30 mm (5 x 5 cm) 44 mm (5 x 5 cm) 22 mm (2.5 x 2.5 cm) 10 mm (2.5 x 2.5 cm) 2.5 mm (2.5 x 2.5 cm)
E32-DC200C
M6 screw **
Flexible spiral cord
E32-DC200D E32-DC200D4
M6 screw **
Flexible spiral cord
E32-DC9G E32-DC9G4
1.2-mm dia. **
T: 35 mm (5 x 5 cm) H: 60 mm (10 x 10 cm) A: 30 mm (5 x 5 cm) F: 9 mm (2.5 x 2.5 cm) V: 2.5 mm (2.5 x 2.5 cm) T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 6 mm (2.5 x 2.5 cm) 10 mm (2.5 x 2.5 cm) 5 mm (2.5 x 2.5 cm) 1.8 mm (2.5 x 2.5 cm) --100 mm (10 x 10 cm) 150 mm (20 x 20 cm) 75 mm (10 x 10 cm) 33 mm (5 x 5 cm) 10 mm (2.5 x 2.5 cm) 30 mm (2.5 x 2.5 cm) 40 mm (5 x 5 cm) 20 mm (2.5 x 2.5 cm) 9 mm (2.5 x 2.5 cm) 2.5 mm (2.5 x 2.5 cm) 60 mm (10 x 10 cm) 80 mm (10 x 10 cm) 40 mm (5 x 5 cm) 11 mm (2.5 x 2.5 cm) 4 mm (2.5 x 2.5 cm)
T: 7 mm (5 x 5 cm) H: 12 mm (10 x 10 cm) A: 6 mm (5 x 5 cm) F: 1.5 mm (2.5 x 2.5 cm) V: --T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 1.3 mm (2.5 x 2.5 cm) 2 mm (2.5 x 2.5 cm) ------20 mm (10 x 10 cm) 30 mm (20 x 20 cm) 15 mm (10 x 10 cm) 6 mm (5 x 5 cm) 2 mm (2.5 x 2.5 cm) 5.3 mm (2.5 x 2.5 cm) 8 mm (5 x 5 cm) 4 mm (2.5 x 2.5 cm) 1.5 mm (2.5 x 2.5 cm) --10 mm (10 x 10 cm) 16 mm (10 x 10 cm) 8 mm (5 x 5 cm) 4 mm (2.5 x 2.5 cm) ---
Stainless steel sleeve
E32-D33
3-mm dia. 0.8-mm dia.
T: 0.015-mm dia. H: 0.015-mm dia. A: 0.015-mm dia. F: 0.03-mm dia. V: --T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 0.5-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 0.5-mm dia. 0.015-mm dia. 0.015-mm dia. 0.04-mm dia. 1.1-mm dia. 1-mm dia. 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 0.5-mm dia. 1.0-mm dia. 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 0.5-mm dia. 0.5-mm dia.
Super-thin; detail sensing
E32-CC200
M6 screw
Coaxial; positioning accuracy
E32-D32
2-mm dia.
General-purpose
E32-D32L
3-mm dia.
General-purpose
E32-D14L
6-mm dia.
T: 40 mm (5 x 5 cm) H: 40 mm (5 x 5 cm) A: 40 mm (5 x 5 cm) F: 12 mm (2.5 x 2.5 cm) V: 1.5 mm (2.5 x 2.5 cm) T: H: A: F: V: 15 mm (2.5 x 2.5 cm) 15 mm (2.5 x 2.5 cm) 15 mm (2.5 x 2.5 cm) 4 mm (2.5 x 2.5 cm) 1.6 mm (2.5 x 2.5 cm)
T: 8 mm (5 x 5 cm) H: 8 mm (5 x 5 cm) A: 8 mm (5 x 5 cm) F: 2 mm (2.5 x 2.5 cm) V: --T: H: A: F: V: 2.5 mm (2.5 x 2.5 cm) 2.5 mm (2.5 x 2.5 cm) 2.5 mm (2.5 x 2.5 cm) -----
Side-view; long distance
E32-D24
2-mm dia.
Side-view; save space
E32-D12F
6-mm dia.
T: 50 mm (5 x 5 cm) H: 50 mm (5 x 5 cm) A: 50 mm (5 x 5 cm) F: 20 mm (2.5 x 2.5 cm) V: 4 mm (2.5 x 2.5 cm)
T: 15 mm (5 x 5 cm) H: 15 mm (5 x 5 cm) A: 15 mm (5 x 5 cm) F: 6 mm (2.5 x 2.5 cm) V: ---
Teflon-covered***; withstands chemicals and harsh environments
*Standard object: opaque **Not trimmable ***Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin.
7
E3X
Model Appearance Sensing distance (standard object) (T: E3X-Tjj; H: E3X-H11; A: E3X-Ajj; F: E3X-Fjj; V: E3X-VGjj) White paper E32-D51
M6 screw
E3X
Min. sensing object (copper wire) Features
Black paper T: H: A: F: V: 12 mm (10 x 10 cm) 24 mm (20 x 20 cm) 12 mm (10 x 10 cm) 5 mm (5 x 5 cm) --T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 0.2-mm dia. 1.0-mm dia. Heat-resistive; resists 150C
T: H: A: F: V:
**
60 mm (10 x 10 cm) 120 mm (20 x 20 cm) 60 mm (10 x 10 cm) 26 mm (5 x 5 cm) 5 mm (2.5 x 2.5 cm)
E32-D61
M6 screw
T: 45 mm (5 x 5 cm) H: 45 mm (5 x 5 cm) A: 45 mm (5 x 5 cm) F: 20 mm (2.5 x 2.5 cm) V: 5 mm (2.5 x 2.5 cm) T: 30 mm (5 x 5 cm) H: 30 mm (5 x 5 cm) A: 30 mm (5 x 5 cm) F: 17 mm (2.5 x 2.5 cm) V: 3 mm (2.5 x 2.5 cm) T: 25 to 250 mm (35-mm dia. min.) H: 10 to 250 mm (35-mm dia. min.) A: 10 to 250 mm (35-mm dia. min.) F: 20 to 230 mm (35-mm dia. min.) V: --T: 150 to 1,500 mm (35-mm dia. min.) H: 150 to 1,500 mm (35-mm dia. min.) A: 150 to 1,500 mm (35-mm dia. min.) F: 50 to 700 mm (35-mm dia. min.) V: --T: H: A: F: V: T: H: A: F: V: 3.3 mm (2.5 x 2.5 cm) 3.3 mm (2.5 x 2.5 cm) 3.3 mm (2.5 x 2.5 cm) 3.3 mm (2.5 x 2.5 cm) --3.3 mm (2.5 x 2.5 cm) 3.3 mm (2.5 x 2.5 cm) 3.3 mm (2.5 x 2.5 cm) 3.3 mm (2.5 x 2.5 cm) ---
T: 9 mm (5 x 5 cm) H: 9 mm (5 x 5 cm) A: 9 mm (5 x 5 cm) F: 4 mm (2.5 x 2.5 cm) V: --T: 6 mm (5 x 5 cm) H: 6 mm (5 x 5 cm) A: 6 mm (5 x 5 cm) F: 3 mm (2.5 x 2.5 cm) V: -----
Heat-resistive; resists 300C
E32-D73
** M4 screw 1.25-mm dia.
Heat-resistive; resists 400C
E32-R21 /E39-R3
M6 screw Reflector E39-R3
T: 0.6-mm dia. H: 0.3-mm dia. A: 0.3-mm dia. F: 0.5-mm dia. V: ---
Transparent objects sensing
E32-R16 /E39-R1
Reflector E39-R1
---
T: 1.9-mm dia. H: 0.6-mm dia. A: 0.6-mm dia. F: 0.6-mm dia. V: ---
Transparent objects sensing
E32-L25
---
T: 0.015-mm dia. H: 0.015-mm dia. A: 0.03-mm dia. F: 0.5-mm dia. V: --T: 0.015-mm dia. H: 0.015-mm dia. A: 0.03-mm dia. F: 0.5-mm dia. V: --H: 0.015-mm dia. A: 0.015-mm dia. F: 0.015-mm dia.
Limited reflective; senses wafers and small difference in height Limited reflective; senses wafers and small difference in height Limited reflective, long distance; senses wafers and small difference in height Limited reflective, long distance, side-view; senses wafers and small difference in height
E32-L25A
---
E32-L25L
H: 7.21.8 mm (2.5 x 2.5 cm) A: 7.21.8 mm (2.5 x 2.5 cm) F: 7.21.0 mm (2.5 x 2.5 cm) H: 42 mm (2.5 x 2.5 cm) A: 42 mm (2.5 x 2.5 cm) F: 42 mm (2.5 x 2.5 cm)
---
E32-L24L
---
H: 0.015-mm dia. A: 0.015-mm dia. F: 0.015-mm dia.
*Standard object: opaque **Not trimmable
8
E3X
Fine Through-beam
Model E32-T22S
1.7 mm dia.
E3X
Appearance Sensing distance (standard object)* H: 1,000 mm (1.7-mm dia. min.) T: 650 mm (1.7-mm dia. min.) H: 700 mm (1.7-mm dia. min.) T: 450 mm (1.7-mm dia. min.) Min. sensing object (opaque objects) H: 0.5-mm dia. T: 0.4-mm dia. H: 0.5-mm dia. T: 0.4-mm dia. Features General purpose Side-view
E32-T24S
3.5 x 3 mm dia.
E32-T84S
H: 700 mm (1.7-mm dia. min.)
H: 0.4-mm dia.
Sensing the wafers in cassettes (Fine, long beam sensor resisting 200C)
*Use the E32-T22S and E32-T24S in combination with the E3X-H11, E3X-T11, or E3X-T21 Amplifier for stable wafer sensing.
Slot Sensors
Model E32-G14 Appearance Sensing distance (standard object)* 10 mm (slot width) (4-mm dia. min.) T: H: A: F: V: Min. sensing object (opaque objects) 0.7-mm dia. 1.0-mm dia. 0.5-mm dia. 0.6-mm dia. 0.6-mm dia. Features Slot through-beam; no optical axis adjustment required
*Standard object: opaque
Liquid Level Fiber Unit
Liquid Contact Model Model Appearance Standard sensing object Pure water at a temperature of 25C. Sensing object angle range 10 max. Repeat frequency 0.5 mm max. Applicable Amplifier Unit (see note) E3X-NT/NM E3X-NV E3X-H
E32-D82F1 E32-D82F2 Note:
When using the E32-D82F1 or E82-D82F2 with the E3X-A, cut the plastic fiber part to 0.5 m, otherwise the energy of the light received by the E3X-A will be insufficient.
Pipe Mounting Model Model E32-L25T Appearance Standard sensing object Liquid (Non-transparent liquids may not be sensed) Repeat frequency 1 mm max. Applicable Amplifier Unit E3X-NT/NM E3X-A/H
9
E3X
High-precision Screen Sensors
Model Appearance Slit width Sensing distance (H: E3X-H11; A: E3X-Ajj; F: E3X-Fjj; V: E3X-VGjj) H: A: H: A: H: A: H: A: F: V: H: A: F: V: H: A: F: V: 600 mm 300 mm 100 mm 50 mm 200 mm 100 mm 1,500 mm 750 mm 330 mm 150 mm 900 mm 450 mm 120 mm 20 mm 1,200 mm 600 mm 250 mm 60 mm H: A: H: A: H: A: H: A: F: V: H: A: F: V: H: A: F: V: Min. sensing object* (horizontal beam) 1.3-mm dia. (1.1-mm dia.) 2.0-mm dia. (0.9-mm dia.) 1.3-mm dia. (0.4-mm dia.) 2.0-mm dia. (0.7-mm dia.) 1.3-mm dia. (0.6-mm dia.) 2.0-mm dia. (0.8-mm dia.) 6.0-mm dia. 6.0-mm dia. 7.0-mm dia. 7.0 mm dia. 5.0-mm dia. 5.0-mm dia. 7.0-mm dia. 7.0-mm dia. 6.0-mm dia. 6.0-mm dia. 7.0-mm dia. 7.0-mm dia.
E3X
E32-T16P
Not used 0.5 mm wide 1.0 mm wide
E32-T16
Not used
0.5 mm wide
1.0 mm wide
*
Values not in parentheses represent sensing objects within the 11-mm sensing area and values in parentheses represent sensing objects in the center of the E32-T16P sensing area. The diameters of sensing objects in the above table represent sensing object sizes, on condition that the objects are not moving. Sensing Direction
Sensing object
Specifications
Amplifier Units
Indicator Sensitivity adjuster Circuit protection Ambient temperature Ambient humidity Ambient illumination Insulation resistance Dielectric strength Enclosure rating Material Connection method Weight (with 2-m cord) Note: Light indicator (red), Stability indicator (green) 8 turns with indicator (except E3X-Tjj) Reverse polarity, Output short-circuit Operating:-25C to 55C (with no icing) Storage: -40C to 70C 35% to 85% (with no condensation) Sunlight: 10,000 x max.; Incandescent lamp: 3,000 x max. 20 MW min. (at 500 VDC) 1,000 VAC, 50/60 Hz for 1 min IEC IP66 (with protective cover in place) (see note) Case: Heat-resistive ABS; Cover: Polycarbonate Cord-drawing method Approx. 100 g
The enclosure rating is IP50 without the protection cover.
10
E3X
Fiber Unit
Through-beam (Separate) Sensors Model E32-T11L E32-T12L E32-T21L E32-T22L E32-TC200 E32-TC200B E32-TC200B4 E32-T22 E32-TC200E E32-TC200F E32-TC200F4 E32-TC200A E32-T11 E32-T21 E32-TC200C E32-TC200D E32-TC200D4 E32-T14L E32-T24 E32-T14 E32-T17L E32-T12F E32-M21 E32-T51 E32-T61 Operating: -30C to 70C (with no icing) Operating: -40C to 70C (with no icing) Operating: -40C to 150C* (with no icing) Operating: -40C to 300C (with no icing) 40 mm min. 25 mm min. 35 mm min. 25 mm min. Teflon-covered black polyethylene Black polyethylene Fluoride resin SUS 25 mm min. Black polyethylene 4 mm min. Vinyl chloride Ambient temperature O ea g Operating: -40C to 70C 0C o 0C (with ( ith no i i ) icing) Ambient humidity Operating: 35% to g 85% Permissible bending radius 25 mm min. Material Black polyethylene
E3X
Enclosure rating IEC IP67
*When used continuously between -40C and 130C.
11
E3X
Reflective Sensors Model E32-D11L E32-D12 E32-D21L E32-D22L E32-DC200 E32-DC200B E32-DC200B4 E32-DC200E E32-DC200F E32-DC200F4 E32-D11 E32-D21 E32-DC200C E32-DC200D E32-DC200D4 E32-DC9G E32-DC9G4 E32-D33 E32-CC200 E32-D32 E32-D32L E32-D14L E32-D24 E32-D12F Operating: -30C to 70C (with no icing) Operating: -40C to 150C (with no icing)** Operating: -40C to 300C (with no icing) Operating: -40C to 400C (with no icing) Operating: -40C to 70C (with no icing) Operating: -25C to 55C (with no icing) Operating: -40C to 70C (with no icing) Operating: -40C to 105C (with no icing) 10 mm min. (average at 10% decrease of sensing distance) Reinforced polyethylene Black polyethylene IEC IP66 40 mm min. Teflon-covered black polyethylene* Fluoride resin 25 mm min. Black polyethylene l th l 4 mm min. Vinyl chloride Differential travel 20% of max. of sensing distance i di t (Adjustable in a range of 0% to 20% when the E3X-H11 is used ) used.) Ambient temperature O ea g Operating: -40C 0C to 70C (with no ( ih icing) Ambient humidity Operating: g 35% t 85% to Permissible bending radius 25 mm min. Material Black polyethylene l th l
E3X
Enclosure rating IEC IP67
E32-D51
35 mm min.
E32-D61
25 mm min.
SUS
E32-D73
E32-R21 E39-R3 E32-R16 E39-R1 E32-L25 E32-L25A E32-L25L***
IEC IP50
E32-L24L***
*Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin. **When used continuously between -40C and 130C. ***Beam size: 2 mm dia.
12
E3X
Fine Through-beam Sensors Model Beam size Differencial travel --Horizontal positioning accuracy --Ambient temperature Operating: -40C to 70C (with no icing) Operating: -40C to 200C (with no icing) Ambient humidity Permissible bending radius* Material
E3X
Enclosure rating IEC IP67
E32-T22S E32-T24S E32-T84S
13 mm dia. (at a distance of 200 mm)
Operating: 10 mm min. 35% to 85% 25 mm min.
Reinforced laminated vinyl chloride SUS
*Average at 30% of sensing distance Slot Sensors Model E32-G14 Ambient temperature Operating: -40C to 70C (with no icing) Ambient humidity Operating: 35% to 85% Permissible bending radius 25 mm min. Material Black polyethylene Enclosure rating IEC IP67
Liquid Contact Model Model Differencial travel Ambient temperature Ambient humidity Ambient pressure Permissible bending radius* (average at 10% of sensing distance)
40 mm min. (plastic fiber: 25 mm min.) Bending-prohibited part: E32-D82F1: Within Withi 150 mm of f fiber tip E32-D82F2: Within 350 mm of fiber tip
Material
Enclosure rating
E32-D82F1
3.0 mm max.
Teflon part within 1.5 m of fiber tip: -40C to 200C (with no icing) Parts other than above: b -40C to 85C (with no icing)
Operating: 35% to 85%
-50 kpa (-0.49 kgf/cm2) to 500 kpa (4.9 kgf/cm2)
Sensing head: Teflon* (PFA) Fiber sheath: Black yy polyethylene Connector: Nickel-coated brass
IEC IP68**
E32-D82F2
*The teflon part located 10 cm underwater must not generate air bubbles when air is injected into the teflon part with a pressure of 98 kpa (1 kgf/cm2). **Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin. Pipe Mounting Model Model Suitable pipe Pipe material Ambient temperature Operating: -40C to 70C (with no icing) Ambient humidity Operating: 35% to 85% Permissible bending radius 10 mm min. Material Enclosure rating IEC IP50
E32-L25T
Transparent pipes with an outer diameter of 8 to 10 mm and an inner diameter of 6 to 8 mm
FEP transparent pipes or equivalent
Sensing head: Polycarbonate Fiber: Polyethylenecovered plastic
High-precision Screen Sensors Model E32-T16P Ambient temperature Operating: -40C to 70C (with no icing) Ambient humidity Operating: 35% to 85% Permissible bending radius R10 mm min. Material Sensing head: Heat-resistive ABS Fiber sheath: Vinyl chloride Sensing head: Heat-resistive ABS Sensing surface: PMMA Fiber sheath: Black polyethylene Enclosure rating IEC IP50
E32-T16
25 mm min.
IEC IP67
13
E3X
Attachments
Name Applications Model Appearance Applicable fibers With E3X-Tjj With E3X-H11 With E3X-Ajj With E3X-Fjj With E3X-VGjj Directivity Differential travel Ambient temperature Material Shaft Lens Base Reflector *E32-T6: 450 mm. **E32-T6: 130 mm. Name Applications Model Appearance Applicable fibers With E3X-Tjj With E3X-H11 With E3X-Ajj With E3X-Fjj With E3X-VGjj Directivity Differential travel Ambient temperature Material Shaft Lens Base Reflector Sensing distance Standard object Sensing distance Standard object Sensing distance Standard object Sensing distance Standard object Sensing distance Standard object E32-T11L 250 mm 400 mm 200 mm 60 mm 10 mm Opaque objects: 4-mm dia. min. 20 to 60 --Operating: -40C to 200C (Do not exceed the operating temperature of the fiber.) Brass Optical glass ----E39-F2
Through-beam (separate)
E3X
Small Spot Lens Unit Sensing over 0.5-mm-dia. spots E39-F3A
Reflective
Long Distance Lens Unit Increasing sensing distance E39-F1
Through-beam (separate)
E32-D32 20 mm White paper 2.5 x 2.5 cm 20 mm White paper 2.5 x 2.5 cm 20 mm White paper 2.5 x 2.5 cm 16 mm White paper 2.5 x 2.5 cm ------20% of sensing distance Operating: -40C to 70C Aluminum Optical glass -----
E32-T11L 1,200 mm 2,000 mm 1,000 mm 550 mm 120 mm 5 to 40 ---
E32-TC200 E32-T61 2,000 mm 3,000 mm 1,500 mm 670 mm* 190 mm**
E32-T11 1,300 mm 2,000 mm 1,000 mm 400 mm 120 mm
E32-TC200C 800 mm 1,600 mm 800 mm 350 mm 100 mm
Sensing distance Standard object Sensing distance Standard object Sensing distance Standard object Sensing distance Standard object Sensing distance Standard object
Opaque objects: 4-mm dia. min. Opaque objects: 4-mm dia. min. Opaque objects: 4-mm dia. min. Opaque objects: 4-mm dia. min. Opaque objects: 4-mm dia. min.
Operating: -40C to 200C (Do not exceed the operating temperature of the fiber.) Brass
Side-view Unit Changing the sensing direction at 90
E32-TC200 250 mm 500 mm 250 mm 100 mm 19 mm
E32-T61/11 200 mm 400 mm 200 mm 60 mm 10 mm
E32-TC200C 100 mm 200 mm 100 mm 30 mm 6 mm
Opaque objects: 3-mm dia. min. Opaque objects: 3-mm dia. min. Opaque objects: 3-mm dia. min. Opaque objects: 3-mm dia. min. Opaque objects: 3-mm dia. min.
14
E3X
Name Applications Model Appearance
Reflective
E3X
Lens-equipped Reflective Unit Converting through-beam sensors to reflective sensors E39-F3
Applicable fibers With E3X-Tjj With E3X-H11 With E3X-Ajj With E3X-Fjj With E3X-VGjj Directivity Differential travel Ambient temperature Material Shaft Lens Base Reflector Sensing distance (standard object) Sensing distance (standard object) Sensing distance (standard object) Sensing distance (standard object) Sensing distance (standard object) White paper Black paper White paper Black paper White paper Black paper White paper Black paper White paper Black paper
E32-T11L 55 to 150* mm (20 x 20 cm) --10 to 300 mm (20 x 20 cm) --10 to 150 mm (20 x 20 cm) --10 to 65 mm (10 x 10 cm) --------20% of sensing distance
E32-TC200 85 to 100 mm (20 x 20* cm) 15 to 17*mm (20 x 20 cm) 35 to 180 mm (20 x 20 cm) 5 to 120 mm (20 x 20 cm) 35 to 90 mm (10 x 10 cm) 5 to 60 mm (10 x 10 cm) 20 to 40 mm (5 x 5 cm) 10 to 20 mm (5 x 5 cm) 10 to 15 mm (2.5 x 2.5 cm)
E32-T61 16 to 18*mm (20 x 20 cm) 5 to 80 mm (20 x 20 cm) 5 to 40 mm (10 x 10 cm) 20 to 35 mm (5 x 5 cm) -----
Operating: -40C to 200C (Do not exceed the operating temperature of the fiber.) Brass Optical glass Aluminum ---
*These values are possible when the angle of the E39-F3 is smallest (parallel).
15
E3X
Name Applications Lens-equipped Reflective Unit Converting through-beam sensors to reflective sensors E39-F3
Reflective
E3X
Side-view Reflective Unit Converting through-beam to reflective sensor E39-F5
Reflective
Model Appearance Applicable fibers With E3X-Tjj With E3X-H11 With E3X-Ajj With E3X-Fjj With E3X-VGjj Directivity Differential travel Ambient temperature Material Shaft Lens Base Reflector Sensing distance (standard object) Sensing distance (standard object) Sensing distance (standard object) Sensing distance (standard object) Sensing distance (standard object) White paper Black paper White paper Black paper White paper Black paper White paper Black paper White paper Black paper
E32-T11 90 to 100* mm (20 x 20 cm) --35 to 180 mm (20 x 20 cm) 5 to 70 mm (20 x 20 cm) 35 to 90 mm (10 x 10 cm) 5 to 35 mm (10 x 10 cm) 20 to 40 mm (5 x 5 cm) --------20% of sensing distance
E32-TC200C 85 to 100* mm (20 x 20 cm)
E32-TC200A 5 to 30* mm (10 x 10 cm) 6 to 9* mm (10 x 10 cm) 60 mm (10 x 10 cm)
10 to 60 mm (20 x 20 cm) 10 to 30 mm (10 x 10 cm) 20 to 35 mm (5 x 5 cm)
5 to 20 mm (10 x 10 cm) 30 mm (5 x 5 cm) 5 to 10 mm (5 x 5 cm) 13 mm (2.5 x 2.5 cm) -----
Operating: -40C to 200C (Do not exceed the operating temperature of the fiber.) Brass Optical glass Aluminum ---
Operating: -40C to 70C ----Brass Stainless
*These values are possible when the angle of the E39-F3 is smallest (parallel).
Beam Spot Characteristics E39-F3A
d Fiber E32-D32 O: Spot diameter (mm) 1.5 1.0
: Insertion distance d: Focal length
Focal length d (mm)
0.8 0.5
Insertion distance
(mm)
16
E3X
Spiral Tubes
Model Appearance E39-F32A5 E39-F32A E39-F32B5 E39-F32B
L
E3X
E39-F32C5 E39-F32C E39-F32D5 E39-F32D
End cap
Tube
Head connector
Length (L) Applicable fiber
500 mm
1,000 mm
500 mm
1,000 mm
500 mm
1,000 mm
500 mm
1,000 mm
E32-DC200E E32-DC200F(4) E32-D21
E32-TC200E E32-TC200F(4) E32-T21 E32-T21L
E32-TC200 E32-TC200B(4) E32-T11 E32-T51 E32-T11L
E32-DC200 E32-DC200B(4) E32-CC200 E32-D11 E32-D51 E32-D11L
Ambient temperature Ambient humidity Permissible bending radius Tensile strength Compression load
Operating: -40C to 150C (Do not exceed the operating temperature of the fiber) Operating: 35% to 85% R: 30 mm min. Between head connector and end cap with tube: 15 kgf $ cm max. (1.5 N $ m) Tube: 20 kgf $ cm max. (2 N $ m) Tube: 3 kg max. (29.4 N)
Accessories
Name Model Appearance Fiber Cutter E39-F4 Fine-fiber Attachment E39-F9 Fiber Connector E39-F10 Sleeve Bender E39-F11
Features Applicable fiber
Used to cut fibers to desired lengths All models equipped with trimmable fibers
Used when inserting fine fibers into the amp E32-DC200E, -TC200E E32-DC200F(4), -TC200F(4) E32-D21, -D21L, -D22L E32-T21, -T21L, -T22L E32-D32, -T22 E32-D24. -T24 E32-D33 E32-R21
Used to connect fibers when broken E32-DC200, -TC200 E32-DC200B(4), -TC200B(4) E32-TC200A E32-T14, -G14 E32-D11L, -T11L, -T12L E32-D14L, -T14L E32-T17L
Used to bend fiber sleeves E32-TC200B(4) E32-TC200D(4) E32-DC200F(4), -TC200F(4) E32-DC9G(4)
17
E3X
E3X
Engineering Data
Excess Gain Ratio
E3X-Tjj
E32-TC200
Sensing distance
E32-T11L
Sensing distance
E32-T11L + E39-F1
Sensing distance
Excess gain ratio
Sensing distance (mm)
Excess gain ratio
Sensing distance (mm)
Excess gain ratio
Sensing distance (m)
E32-T11L + E39-F2
E32-T11L + E39-F3
(When the angle of the E39-F3 is at its minimum (parallel).)
Sensing distance Sensing object
E32-T21L
Sensing distance
Excess gain ratio
Excess gain ratio
Sensing distance
Sensing distance (mm)
Sensing distance (mm)
Excess gain ratio
Sensing distance (mm)
E32-T14L
Sensing distance
E32-T17L
Sensing distance
E32-T16
Sensing distance
Excess gain ratio
Sensing distance (mm)
Excess gain ratio
Sensing distance (m)
Excess gain ratio
Sensing distance (m)
18
E3X
E32-DC200
Sensing distance
E3X
E32-D11L
Sensing distance
E32-D21L
Sensing distance
Excess gain ratio
Sensing distance (mm)
Excess gain ratio
Sensing distance (mm)
Excess gain ratio
Sensing object
Sensing object
Sensing object
Sensing distance (mm)
E3X-H11
E32-TC200
Sensing distance
E32-TC200 + E39-F1
Sensing distance
E32-T11L
Sensing distance
Excess gain ratio
Sensing distance (mm)
Excess gain ratio
Sensing distance (m)
Excess gain ratio
Sensing distance (mm)
E32-T11L + E39-F1
Sensing distance
E32-T11L + E39-F2
Sensing distance
E32-T11L + E39-F3
Sensing object
Excess gain ratio
Excess gain ratio
Sensing distance (m)
Excess gain ratio
Sensing distance
Sensing distance (mm)
Sensing distance (mm)
19
E3X
E32-T21L
Sensing distance
E3X
E32-T14L
Sensing distance
E32-T17L
Sensing distance
Excess gain ratio
Sensing distance (mm)
Excess gain ratio
Sensing distance (mm)
Excess gain ratio
Sensing distance (m)
E32-T16
Sensing distance
E32-T22S
Sensing distance
E32-T24S
Sensing distance
Excess gain ratio
Excess gain ratio
Sensing distance (m)
Sensing distance (mm)
Excess gain ratio
Sensing distance (mm)
E32-DC200
Sensing distance
E32-D11L
Sensing distance
E32-D21L
Sensing distance
Excess gain ratio
Excess gain ratio
Sensing distance (mm)
Sensing distance (mm)
Excess gain ratio
Sensing object
Sensing object
Sensing distance (mm)
20
E3X
E32-T84S
Sensing distance
E3X
Excess gain ratio
Sensing distance (mm)
E3X-Ajj/-Fjj/-VGjj
E32-T11L, E32-T12L
Sensing distance
E32-T11L + E39-F1
Sensing distance
E32-T11L + E39-F2
Sensing distance
Excess gain ratio
Excess gain ratio
Excess gain ratio
E3X-Aj E3X-Fj
E3X-Aj
E3X-Aj E3X-Fj
E3X-Fj Operating level
Operating level E3X-VGj E3X-VGj
Operating level
E3X-VGj
Sensing distance (mm)
Sensing distance (cm)
Sensing distance (mm)
E32-T11L + E39-F3
Sensing object
E32-T21L, E32-T22L
Sensing distance
E32-T14L
Sensing distance
Excess gain ratio
Sensing distance
E3X-Aj
Excess gain ratio
E3X-Aj E3X-Fj
Excess gain ratio
E3X-Aj E3X-Fj
E3X-Fj Operating level Operating level
E3X-VGj
E3X-VGj
Operating level
Sensing distance (mm)
Sensing distance (mm)
Sensing distance (mm)
21
E3X
E32-T17L
Sensing distance
E3X
E32-T12F
Sensing distance
E32-D11L
Sensing distance
Excess gain ratio
E3X-Aj E3X-Fj
Excess gain ratio
E3X-Aj E3X-Fj
Excess gain ratio
Sensing object
E3X-Aj E3X-Fj
Operating level E3X-VGj E3X-VGj
Operating level E3X-VGj
Operating level
Sensing distance (m)
Sensing distance (cm)
Sensing distance (mm)
E32-D21L, E32-D22L
Sensing distance
E32-D14L
Sensing distance
E32-D12F
Sensing distance Sensing object
Sensing object
Excess gain ratio
Excess gain ratio
E3X-Aj E3X-Fj
E3X-Aj
Excess gain ratio
Sensing object
E3X-Aj E3X-Fj
E3X-Fj Operating level E3X-VGj E3X-VGj
Operating level E3X-VGj
Operating level
Sensing distance (mm)
Sensing distance (mm)
Sensing distance (mm)
Operating Range
E3X-Tjj
E32-DC200
Operating position Y (mm)
X Y
E32-D11L
Operating position Y (mm)
X Y
Set distance X (mm)
Set distance X (mm)
E32-D21L
Operating position Y (mm)
X Y
Set distance X (mm)
22
E3X
E3X-H11
E32-T11L + E39-F3
Operating position Y (mm)
E3X
E32-DC200
Operating position Y (mm)
E32-D11L
Operating position Y (mm)
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
Sensing object
Sensing object
Sensing object
E32-D12
Operating position Y (mm)
E32-D21L
Operating position Y (mm)
E32-DC200E
Operating position Y (mm)
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
Sensing object
Sensing object
Sensing object
E32-D21
Operating position Y (mm)
E32-D11
Operating position Y (mm)
E32-CC200
Operating position Y (mm)
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
Sensing object
Sensing object
Sensing object
E32-D32
Operating position Y (mm)
E32-D32L
Operating position Y (mm)
E32-D33
Operating position Y (mm)
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
E32-D51
Operating position Y (mm)
E32-L25L
Operating position Y (mm)
E32-T84S
Operating position Y (mm)
Set distance X (mm)
Set distance X (mm)
Operating position Y Sensing object Sensing object Set distance X
Set distance X (mm)
Sensing object
Set distance X
23
E3X
E3X-Ajj/-Fjj/-VGjj
E32-T11L + E39-F3
Operating position Y (mm)
E3X-Fj E3X-Aj
E3X
E32-DC200
Operating position Y (mm)
E32-D11L
Operating position Y (mm)
E3X-VGj E3X-Aj
E3X-Aj
E3X-Fj Set distance X (mm)
E3X-Fj Set distance X (mm)
Set distance X (mm)
Sensing object
Sensing object
Sensing object
Note:
With E3X-A: Adjust the angle of E39-F3 so that the sensor can sense an object at a distance of 90 mm. (For E3X-F: 50 mm)
E32-D12
Operating position Y (mm)
E32-D21L + E32-D22L
Operating position Y (mm)
E32-DC200E
Operating position Y (mm)
E3X-VGj Amplifier
E3X-Aj Amplifier
E3X-Fj
E3X-Aj
E3X-Aj
E3X-Fj Amplifier
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
Sensing object
Sensing object
Sensing object
E32-D21
Operating position Y (mm)
E32-D11
Operating position Y (mm)
E32-D33
Operating position Y (mm)
E3X-VGj E3X-Fj E3X-Aj
E3X-Aj
E3X-Aj
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
Sensing object
Sensing object
E32-CC200
Operating position Y (mm)
E32-D32L
Operating position Y (mm)
E32-D14L
Operating position Y (mm)
E3X-VGj E3X-Aj E3X-Fj
E3X-Fj
E3X-Aj
E3X-VGj Amplifier E3X-Fj Amplifier E3X-Aj Amplifier
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
Sensing object
24
E3X
E32-D24
Operating position Y (mm)
E3X
E32-D12F
E3X-Aj E3X-VGj E3X-Fj
E32-D51
E3X-Fj E3X-Aj
Operating position Y (mm)
E3X-Fj
E3X-Aj
Operating position Y (mm)
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
Sensing object
Sensing object
E32-D61
Operating position Y (mm)
E32-D73
Operating position Y (mm)
E32-R16
Operating position Y (mm)
E3X-Aj
E3X-Fj
E3X-Aj
E3X-Fj
E3X-Aj
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
Sensing object
Sensing object
Sensing object
E32-L25L
Operating position Y (mm)
Set distance X (mm)
Operating Sensing object position Y Sensing object Set distance X
Set distance X
25
E3X
Parallel Operating Range (Typical)
E3X-Tjj
E32-TC200
Parallel operating range Y (mm)
X Y
E3X
E32-T11L
Parallel operating range Y (mm)
X Y
Set distance X (mm)
Set distance X (mm)
E32-T11L +E39-F1
Parallel operating range Y (cm)
X Y
E32-T11L + E39-F2
Parallel operating range Y (mm)
X Y
Set distance X (m)
Set distance X (mm)
E32-T21L
Parallel operating range Y (mm)
X Y
E32-T14L
Parallel operating range Y (mm)
X Y
Set distance X (mm)
Set distance X (mm)
E32-T17L
Parallel operating range Y (cm)
X Y
E32-T12F
Parallel operating range Y (cm)
X Y
Set distance X (m)
Set distance X (m)
26
E3X
E3X-H11
E32-TC200
Operating position Y (mm)
E3X
E32-TC200 + E39-F2
Operating position Y (mm)
E32-T11L
Operating position Y (mm)
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
E32-T11L + E39-F1
Operating position Y (mm)
E32-T11L + E39-F2
Operating position Y (mm)
E32-T21L
Operating position Y (mm)
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
E32-T21L
Operating position Y (mm)
E32-T22
Operating position Y (mm)
E32-T11
Operating position Y (mm)
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
E32-T21
Operating position Y (mm)
E32-T14L
Operating position Y (mm)
E32-T24
Operating position Y (mm)
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
E32-T14
Operating position Y (mm)
E32-T17L
E32-T12F
Operating position Y (mm)
Set distance X (mm)
Set distance X (mm)
Operating position Y (mm)
Set distance X (mm)
27
E3X
E32-M21
Operating position Y (mm)
E3X
E32-T51
Operating position Y (mm)
E32-T61
Operating position Y (mm)
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
E32-T22S
Operating position Y (mm)
E32-T24S
Operating position Y (mm)
Set distance X (mm)
Set distance X (mm)
E3X-Ajj/-Fjj/-VGjj
E32-TC200
Operating position Y (mm)
E3X-Aj E3X-VGj E3X-Fj
E32-TC200 + E39-F2
Operating position Y (mm)
E3X-Aj
E32-T11L/-T12L
Operating position Y (mm)
E3X-VGj E3X-Fj E3X-Aj
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
E32-T11L + E39-F1
Operating position Y (mm)
E3X-VGj E3X-Fj E3X-Aj
E32-T11L + E39-F2
E3X-VGj E3X-Aj
E32-T21L/-T22L
E3X-Aj
Operating position Y (mm)
Operating position Y (mm)
E3X-VGj E3X-Fj
E3X-Fj
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
28
E3X
E32-TC200E
E3X-VGj E3X-Aj
E3X
E32-T11
E3X-VGj E3X-Aj
E32-T21
E3X-Aj
Operating position Y (mm)
Operating position Y (mm)
Operating position Y (mm)
E3X-Fj
E3X-Fj
E3X-Fj
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
E32-T14L
Operating position Y (mm)
E3X-VGj E3X-Fj E3X-Aj
E32-T24
E3X-VGj E3X-Aj
E32-T14
E3X-Fj E3X-Aj
Operating position Y (mm)
Operating position Y (mm)
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
E32-T17L
E3X-Aj
E32-T12F
E3X-Aj
E32-M21
E3X-Aj
Operating position Y (mm)
Operating position Y (mm)
Operating position Y (mm)
E3X-VGj E3X-Fj
E3X-VGj E3X-Fj
E3X-F21
Set distance X (mm)
Set distance X (mm)
Set distance X (mm)
E32-T51
E3X-Aj
E32-T61
E3X-Aj
E32-T61 + E39-F1
E3X-Aj
Operating position Y (mm)
Operating position Y (mm)
E3X-Fj
Set distance X (mm)
Operating position Y (mm)
Set distance X (mm)
Set distance X (mm)
E32-T22S
Operating position Y (mm)
E3X-VGj E3X-Aj
E32-T24S
E3X-Aj
Operating position Y (mm)
E3X-VGj
E3X-Fj
E3X-Fj
Set distance X (mm)
Set distance X (mm)
29
E3X
Number of Turns of Sensitivity Adjuster and Sensing Distance (Typical) E3X-H/E32-D11L
Sensing Object: White Paper of 5 x 5 cm
E3X
E3X-A, -F/E32-D11L
Sensing Object: White Paper of 10 x 10 cm with E3X-A and 5 x 5 cm with E3X-F
Sensing distance (mm)
Sensing distance (mm)
E3X-Aj
E3X-Fj
Sensitivity adjuster
Sensitivity adjuster
Color Sensing (Typical) Green Light Source E3X-VGj /E32-D11L
The following graph shows the relationship between colors and the number of turns of the sensitivity adjustor when the E32-D11L is in operation with the sensing distance adjusted to 5 mm. Munsell chroma (MC)
White CM484 Yellow CM124 Amber CM 78 Yellow green CM157 Orange CM 85 Aqua CM263 Red CM 6 Purple CM379 Magenta CM431 Blue CM336 Green CM241 Black CM489 10 Color paper (2.5 x 2.5 cm) 5 mm
Number of turns
30
E3X
E3X
Nomenclature
E3X-Tjj E3X-H11
Stable Operation Indicator (Green Indicator) Tuning Indicator (Two Colors: red/green indicator) Tuning Button Light Reception Indicator (Red Indicator) Stable Operation Indicator (Green Indicator) Sensitivity Indicator The position of the indicator can be checked. 8-turn Sensitivity Adjuster Light Reception Indicator (Red Indicator)
Mode Setting Selector Timer Switch ON: Timer function is ON. OFF: Timer function is OFF.
Hysteresis Adjuster Timer Switch ON: Timer function is ON. OFF: Timer function is OFF.
Operation Mode Selector L-ON: Output transistor is ON when light is received. D-ON: Output transistor is ON when light is not received.
Mode Selector SET: The light source flashes. Set to this mode to adjust the light axis. Light Reception L-ON: Output transistor is ON Monitoring Terminal when light is received. (see note) D-ON: Output transistor is ON Monitoring is used when light is not rewith the E39-VX ceived. Beam Checker
Light Reception Monitoring Terminal Monitoring is used with the E39-VX Beam Checker
Note:
The light reception monitoring terminal is not available with the E3X-T11.
E3X-A11/-A41 E3X-VG11
E3X-A21/-A51 E3X-F21/-F51 E3X-VG21
Light Reception Indicator (Red Indicator) Sensitivity Indicator Sensitivity adjustment can be checked visually. Stable Operation Indicator (Green Indicator) Sensitivity Indicator Light Reception Indicator (Red Indicator)
Stable Operation Indicator (Green Indicator)
8-turn Sensitivity Adjuster
8-turn Sensitivity Adjuster
Timer Adjuster
Timer Switch ON: Timer function is ON. OFF: Timer function is OFF. Mode Selector Light Reception SET: The light source Monitoring Terminal flashes. Set to this Monitoring is used mode to adjust the with the E39-VX light axis. Beam Checker L-ON: Output transistor is ON when light is received. D-ON: Output transistor is ON when light is not received. Note: Set the mode selector to L-ON or D-ON after the light axis is adjusted. Mode Selector SET: The light source flashes. Set to this mode to adjust the light axis. L-ON: Output transistor is ON when light is received. D-ON: Output transistor is ON when light is not received. Light Reception Monitoring Terminal Monitoring is used with the E39-VX Beam Checker
31
E3X
E3X
Operation
Output Circuits
Type NPN Model E3X-T21 Mode switch Light ON Output transistor ON when light is received.
Light (red) Stability (green)
Output circuit
Tuning (red/ green)
Brown Black Load
Main circuit ZD
Load Orange Control output ZD Blue Remote tuning input Remote bank selection input ZD : VZ = 39 V Self-diagnostis Self diagnostis tt output
Dark ON
ON when light is not received.
Pink Purple
E3X-T11 E3x-H11 E3X-A11 E3X-VG11
Light ON
ON when light is received.
Light (red)
Brown Stability (green) Load Main circuit Black 100 mA max. ZD Blue ZD : VZ = 39 V
Dark ON
ON when light is not received. ON when light is received.
E3X-A21 E3X-VG21 E3X-F21
Light ON
Light (red)
Stability (green)
Brown Load (Relay)
Main circuit
Black ZD Control output
Load (Relay)
Dark ON
ON when light is not received.
g Orange Self-diagnosis output ZD 10 K Pink Externalcheck input
Blue ZD : VZ = 39 V
PNP
E3X-A41
Light ON
ON when light is received.
Light (red)
Stability (green) ZD Main circuit
Brown
Black 100 mA max. Load Blue ZD : VZ = 39 V
Dark ON
ON when light is not received.
E3X-A51 E3X-F51
Light ON
ON when light is received.
Light (red) Stability (green) 10 K ZD Orange
Brown
Pink
External-check input Self-diagnosis output
Dark ON
ON when light is not received.
Main circuit
ZD Black
Control output Load (Relay) Blue ZD : VZ = 39 V
Load (Relay)
32
E3X
Timing Charts
Type NPN Model E3X-T21 Mode switch Light ON Output transistor ON when light is received.
Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release (Between brown and black)
E3X
Timing chart
T
Dark ON
ON when light is not received.
Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release
T
(Between brown and black)
E3X-T11 E3X-H11 E3X-A11 E3X-VG11
Light ON
ON when light is received.
Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release (Between brown and black)
Dark ON
ON when light is not received.
Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release T (Between brown and black)
E3X-A21 E3X-VG21 E3X-F21
Light ON
ON when light is received.
Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release
(Between brown and black)
Dark ON
ON when light is not received.
Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release
T
(Between brown and black)
33
E3X
Type PNP Model E3X-A41 Mode switch Light ON Output transistor ON when light is received.
Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release (Between blue and black)
E3X
Timing chart
Dark ON
ON when light is not received.
Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release (Between blue and black)
E3X-A51 E3X-F51
Light ON
ON when light is received.
Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release
T
(Between blue and black)
Dark ON
ON when light is not received.
Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release
T
(Between blue and black)
34
E3X
Sensitivity Adjustment
E3X-Tjj
1. Locate the sensor head in the sensing range of the E3X. 2. Set the mode selector to TUNING. 3. Locate the object at the sensing position and press the tuning button. Through-beam Model Reflective Model Reflective Model
E3X
Mark
Light is not received. Base
The tuning indicator (red) is lit. The built-in buzzer beeps once. 4. Move the object and press the tuning button. Through-beam Model Reflective Model Reflective Model
Mark
Light is received.. Base
The tuning indicator turns green. The built-in buzzer beeps once. If tuning is NG: The tuning indicator (red) is still lit. The built-in buzzer beeps 3 times. Change the position of the object and the sensing distance that have been set and repeat from the beginning. 5. Set the mode setting selector to RUN to complete the sensitivity setting on the E3X. The tuning indicator (green) is OFF. 6. Select the logical output required with the operation mode selector. Maximum Sensitivity Setting 1. Set the mode setting selector to TUNING. 2. Press the tuning button, at which time the object may or may not be located at the sensing position. The tuning indicator (red) is lit. The built-in buzzer beeps once. 3. Set the mode setting selector to RUN to complete the maximum sensitivity setting on the E3X. It will take approximately three seconds for the stable operation indicator or light reception indicator to be lit. After the maximum sensitivity setting is completed, the tuning indicator will turn green and then it will be automatically turned OFF in approximately three seconds. The maximum sensitivity of the E3X can be automatically set regardless of the set distance or light reception. Note: The sensitivity of the E3X-T11 and E3X-T21 are set to maximum before shipping.
If tuning is OK:
35
E3X
E3X-H11/-Ajj/-Fjj/-VGjj
Using a sensing object, adjust Sensitivity Adjustor so that the indicators operate as described in the following table: Sensing method Through-beam
With sensing object
E3X
Sensing
Light Interrupted
Indicators
Green: Light ON Red: Light OFF
Incident
Without sensing object Green: Light ON Red: Light ON
Reflective
Sensing
With sensing object
Incident
Green: Light ON Red: Light ON Without sensing object
Interrupted
Green: Light ON Red: Light OFF
Sensing of the difference in color or shade
Incident
Color that has a high reflection ratio Green: Light ON Red: Light ON
Interrupted
Color that has a low reflection ratio Green: Light ON Red: Light OFF
Retroreflective
With sensing object Reflector
Interrupted
Green: Light ON Red: Light OFF
Incident
Without sensing object Reflector Green: Light ON Red: Light ON
Note:
1. If the indicators operate as described in the table, the E3X can operate in stable condition within the rated temperature range. 2. Even when the green indicator is OFF, the E3X will operate stably if the operating temperature change since the initial settings is within +10C.
36
Light Axis Adjustment with Flashing Function E3X-Tjj
This function enables the user to adjust with ease the light axis of the through-beam fiber with the light source flashing. All E3X models have this function. 1. Set the mode setting selector to FLASH. 2. If the axis of the light emission fiber head and that of the light reception fiber head do not agree with each other and the amount of light reception becomes 90% of the peak value or less, the flashing function of the E3X will work. The E3X retains the peak value when the mode setting selector is set to FLASH and the axes of the fiber heads are adjusted to agree with each other.
Mode Setting Selector
Fiber for light emission
Fiber for light reception
Optical input The peak of light reception 90% of the peak value
Lit in this range.
Angle of the head () Flashing Lit Flashing
E3X-Ajj/-Fjj/-VGjj
1. Set the mode selector to SET. 2. Adjust the light axis by moving the fiber with the light flashing. Improper Light Axis Proper Light Axis Flashing Light ON with no flushing Light axis adjusted
Mode Selector
3. Set the mode selector to L-ON or D-ON after the light axis is adjusted.
1 37
E3X
Self-diagnostic Function
With this function, the E3X checks changes in environmental conditions (especially a change in the ambient temperature) and self-diagnoses the resistance against the changes. The result is shown by the indicators or an output signal. Stable Operation Indicator (Green Indicator) Light Reception Indicator (Red Indicator) Displays
E3X
*
Stable Operation Indicator: Changes in environmental conditions (changes in the ambient temperature, the operating voltage, or the volume of dust) are checked and the resistance against them are self-diagnosed. The result is shown via the indicator. Light Reception Indicator: The amount of light received is indicated by this indicator. The resistance against changes in environmental conditions is indicated by the indicator and the result is output.
* *
Output
Amount of light 1.2 1 0.8
Operating level x 1.2 Operating level Operating level x 0.8
Control output (L-ON)
ON OFF 0.3 s min. 0.3 s min.
ON Self-diagnostic output* OFF
Indicator
Tip of the fiber connected to the light source side in the SET mode
*If the self-diagnostic output is ON when the sensing object is moving at low speed, use the E3X with an ON-delay timer circuit.
Remote Tuning/Remote Bank Function (E3X-T21)
Remote Tuning Function
Basically, the method of remote tuning is same as that of sensitivity adjustment. When the remote tuning function of the E3X is used, the E3X is tuned with the remote tuning input signal instead of the tuning button which has to be pressed. 1. Set the mode selector to RUN. 2. The following signal conditions must be given as remote tuning input conditions.
Brown +V
Black; control output Orange; self-diagnostis output Purple; remote bank selection Pink
Blue 0 V
If no remote tuning is done, cut off the purple wire at its source or connect the pink wire to the positive terminal of the power supply.
2 38
EEEEE EEE EEEEE EE EEEE EEE IIIII EEEE IIIII EE
Red Green Green Green Flashing light ON Flashing
E3X
Power supply
ON OFF
E3X
Remote tuning input
Sensitivity setting
H L
T1
T2
T1
T1: 0.5 to 3 s
T2: 0.5 to 1 s min. T2
Maximum sensitivity
H L
T2: 5 s min.
Remote Bank Function
The remote bank input signal allows the setting of two kinds of sensitivity adjustment values.
Brown +V
Black; control output Orange; self-diagnosis input Pink Purple
Bank 1: SW = OFF Bank 2: SW = ON
Blue 0 V
To set two kinds of sensitivity adjustment values, the purple and blue wires must be connected with each other and select bank 2 to tune the E3X.
Variable Hysteresis Function (E3X-H11)
Sensing of Plate Level Differences
(If sensing is impossible with the hysteresis value set to maximum)
Reflection of light Reflection of light Reflection of light
Refer to the following when using the hysteresis adjuster.
ON Large hysteresis differential OFF
ON Small hysteresis differential ON OFF
OFF
A ON
B Unstable
A Unstable
B OFF
A ON
B OFF
Sensing operation is not stable because zone B is within the hysteresis differential range.
Reduce the sensitivity of the E3X with the sensitivity adjuster and turn off zone B.
Reduce the hysteresis value with the hysteresis adjuster so that zone A will be ON.
3 39
E3X
Set both the sensitivity adjuster and hysteresis adjuster to maximum.
12 SENS min max
E3X
min
max
Hysteresis differential adjuster
Sensitivity adjuster Decide the position of the fiber head and that of the sensing object in zone A.
(E)
Locate the head in zone A and turn the sensitivity adjuster counterclockwise slowly until the stable operation indicator and light reception indicator are OFF (i.e., position E as shown in the illustration).
12 SENS
min
max
When the head is located in zone B, light reception indicator is lit. YES
NO
S
L
Locate the head in zone B and turn the hysteresis adjuster counterclockwise slowly and make sure that the light reception indicator is lit. YES
min
max
NO Set the hysteresis adjuster to maximum.
min max
S
L
S
L S L
(H) min max
Set the hysteresis adjuster to the point where the light reception indicator is lit (i.e., position E as shown in the illustration).
Locate the head in zone A and turn the sensitivity adjuster clockwise until the stable operation indicator and light reception indicator are OFF (i.e., position F as shown in the illustration).
(F) (G)
12 SENS
min
max
(E)
The light reception indicator is lit when the head is located in zone B and the light reception indicator is OFF when the head is located in zone A.
NO
S
L
Locate the head in zone A and turn the sensitivity adjuster counterclockwise until the light reception indicator and stable operation indicator are OFF (i.e., position O as shown in the illustration).
(G) 12 SENS
min
max
YES Sensing is possible.
S
L
B
A
4 40
E3X
External Diagnostic Input Function
With this function, light projection can be stopped when desired. The operation of the sensor can be checked with this function before the E3X is placed into actual operation. E3X-Ajj Light is emitted from the projection fiber head when the self-diagnostic input is ON. The sensor, however, will not operate. NPN Type
Brown (+V) Pink (externalcheck Input) ON Indicator Blue (0 V) Brown (+V) Pink (externalcheck Input) OFF Blue (0 V) External-diagnostic input (between blue and pink) LED for light projection Short Open ON OFF ON OFF
E3X
E3X-Fjj/-VGjj No light is emitted from the projection fiber head when self-diagnostic input is ON.
Light projection stops
Light
By short-circuiting the pink and blue cords, light projection can be stopped (with a short-circuit current of 0.2 mA max.).
PNP Type
Brown (+V) ON Pink (externalcheck Input) Blue (0 V) Brown (+V) External-diagnostic input Short (between brown and pink) Open LED for light projection ON OFF ON OFF
Light projection stops
Indicator
OFF Light Pink (externalcheck Input) Blue (0 V)
By short-circuiting the brown and pink cords, light projection can be stopped (with a short-circuit current of 0.2 mA max.).
Special Fiber Units
The following special accessories are available (order separately). Contact your OMRON representative for the details. Appearance
L
Fiber Units with Special Length of Stainless Steel Tube
Fiber with different lengths of stainless steel tubes are available. Applicable Models E32-TC200F (tube with 0.9 dia.) E32-TC200B/DC200F (tube with 1.2 dia.) E32-DC200B (tube with 2.5 dia.)
The length can be ordered in increments of 10 mm between 10 mm min. and 120 mm max. Tolerance: +1.0 mm if L is 40 mm or less. and +2.0 if L is more than 40 mm. (Note that standard Fiber Units have a 90-mm or 40-mm long stainless steel tube.)
5 41
E3X
Fiber Units with 90 Bend in Stainless Steel Tube
Applicable Models E32-TC200B/TC200F/DC200F Appearance Stainless Steel Tube with a 90 Bend at the Tip
Length R
E3X
Stainless Steel Tube with a 90 Bend at the Base
Length
2
R
Bending radius R 5.0 R 7.5 R 10.0 R 12.5 5.0 mm 7.5 mm 10.0 mm 12.5 mm
1
1
(+1) 10.0 mm 17.5 mm 20.0 mm 22.5 mm
Bending radius R 5.0 R 7.5 R 10.0 R 12.5 10.0 mm 12.5 mm 15.0 mm 17.5 mm
1
(+1) 15.0 mm 17.5 mm 20.0 mm 22.5 mm
The length overall is 120 mm max. Note: If larger 2 is required, use the E39-F11 Sleeve Bender.
The length overall is 120 mm max. Note: If larger 1 is required, use the E39-F11 Sleeve Bender. Sensing Distance for Tubes with 90 Bends Model E32-TC200B Amplifier Standard E3X-Tjj E3X-H11 E3X-Ajj E32-TC200F E3X-Tjj E3X-H11 E3X-Ajj E32-DC200F E3X-Tjj E3X-H11 E3X-Ajj 270 mm 400 mm 180 mm 65 mm 100 mm 50 mm 20 mm 36 mm 18 mm Bending radius R5.0 170 mm 260 mm 110 mm 30 mm 55 mm 30 mm 15 mm 30 mm 10 mm R7.5 220 mm 330 mm 140 mm 65 mm 100 mm 50 mm 20 mm 36 mm 18 mm R10.0 240 mm 360 mm 160 mm 65 mm 100 mm 50 mm 20 mm 36 mm 18 mm R12.5 270 mm 400 mm 180 mm 65 mm 100 mm 50 mm 20 mm 36 mm 18 mm
Fiber Unit with Longer Fiber
Applicable Models E32-TC200/-DC200 E32-TC200B/-DC200B E32-TC200E/-DC200E E32-TC200F/-DC200F E32-TC200A Appearance
The length can be ordered in increments of 1 m between 6 m min. and 20 m max.. (2-m and 5-m fiber length types are standard for E32-TC200, E32-DC200.)
6 42
E3X
Fiber Length vs. Sensing Distance
Through-beam Fiber Unit (Based on the sensing distance using a fiber length of 2 m as 100%) Sensing distance (%) Reflective Fiber Unit (Based on the sensing distance using a fiber length of 2 m as 100%) Sensing distance (%)
E3X
Fiber length (m) E3X-Ajj, E32-TC200 (Typical) Sensing distance (mm)
Fiber length (m) E3X-Ajj, E32-DC200 (Typical) Sensing distance (mm)
Fiber length (m)
Fiber length (m)
43 7
E3X
E3X
Dimensions
Fiber Units
Through-beam (Sold in Pairs)
E32-T11L
M2.6 x 1.4 dia. 0.45 Two hexagon clamping nuts (T = 2.4) Two toothed washers (for M4) Optical fiber, 2.2 dia. Sensing head (nickelplated brass) M4x0.7
E32-T12L
1.4 dia. 2.4 dia. Sensing head (nickel-plated brass) 3 dia. Optical fiber, 2.2 dia.
3.2 7
3
11 (14)
3 2,000
11 (14) 2,000
E32-T21L
Two hexagon clamping nuts Two toothed washers Sensing head M3 x 0.5 (nickel-plated brass) Optical fiber, 1 dia. Fiber attachment (E39-F9) 25 10
E32-T22L
Sensing head, 2 dia. (stainless) Heat-shrinkable tubing Optical fiber, 1 dia. Fiber attachment (E39-F9) 25 10
0.9 dia.
0.9 dia.
1.8 dia.
(2) 2.5 5.5 (1.7) 11 1.8 2,000 17 22 12 2,000
E32-TC200
Two hexagon clamping nuts Two toothed washers M2.6 x 0.45 Sensing head M4 x 0.7 (nickel-plated brass)
E32-TC200B E32-TC200B4
1.0 dia. 1.2 dia max. Stainless tube (SUS304) Two hexagon clamping nuts Two toothed washers Sensing head M4 x 0.7 (nickel-plated brass)
1.0 dia.
3.2 7
3
14
2.4
Optical fiber, 2.2 dia. 2,000
3.2 7
2.4 11 90 (40) (see note)
Optical fiber, 2.2 dia. 2,000
Note:
The value in the parentheses is for the E32-TC200B4.
Two hexagon clamping nuts Two toothed washers Sensing head M3 x 0.5 (nickel-plated brass) Optical fiber, 1 dia. Fiber attachment (E39-F9) 25 10
E32-T22
Heat-shrinkable tubing 0.5 dia. Sensing head SUS303 1.4 dia. Optical fiber, 1 dia. Fiber attachment (E39-F9) 25 10
E32-TC200E
0.5 dia.
2 dia.
17 22
12 2,000
2.5 5.5
1.8 11 2,000
E32-TC200F E32-TC200F4
0.5 dia. 0.9 dia. min. Stainless tube (SUS304)
Two hexagon clamping nuts Two toothed washers Sensing head M3 x 0.5 (nickel-plated brass) Optical fiber, 1 dia.
Fiber attachment (E39-F9) 25 10
Note:
2.5 5.5 1.8 11 90 (40) (see note) 2,000
The value in the parentheses is for the E32-TC200F4.
E32-TC200A
1.0 dia. Two hexagon clamping nuts Two toothed washers 2.6 dia. Sensing head M3 x 0.5 (nickel-plated brass)
E32-T11
Sensing head (nickelSixteen, plated brass) Two hexagon clamping nuts Two toothed washers 0.265 dia. M4 x 0.7 Protective tube Optical fiber, 2.2 dia. M2.6 x 0.45 3.3 15 2,000
1.8 5.5 (1.5) 7 14
3 dia.
Optical fiber, 2.2 dia. 2,000
3.2 7
2.4 (14)
1 44
E3X
E32-T21
Sensing head (nickel-plated brass) M3 x 0.5 Two hexagon clamping nuts Four, 0.25 dia. Two toothed washers Protective tube Fiber attachment (E39-F9) 25 10 Optical fiber, 1 dia.
E3X
2.5 5.5
1.8 11
15 2,000
E32-TC200C
1.0 dia. Two hexagon clamping nuts Two toothed washers Sensing head M4x0.7 (nickelM2.6 x 0.45 plated brass) Optical fiber, 2.2 dia. 90 2,000 (when straight) 400 (75)
22 dia. 7 3 2.4 11
E32-TC200D E32-TC200D4
Two hexagon clamping nuts Stainless Two toothed washers tube Sensing head M4 x 1.0 dia. (SUS304) 0.7 (nickel-plated 1.2 brass) dia. max. 2.4 3.2 7 11 90 (40) (see note) Optical fiber, 2.2 dia. 90
(75)
22 dia.
Note:
400
The value in the parentheses is for the E32-TC200D4.
2,000 (when straight) Heat-shrinking tubing
E32-T14L
45 2.8 1.5 1 1.5
Sensing head, 3 dia. (stainless)
Optical fiber, 2.2 dia.
3dia
30 35 Sensing surface
12 2,000
E32-T24
Sensing head 1 dia. SUS304 2 dia. 45% 1 0.5 1.4 dia. Protective tube Optical fiber, 1 dia. 10
Fiber attachment (E39-F9) 25
1.5 15 35
15
12 2,000
E32-T14
Heat resistive ABS Lens unit (PMMA) 4.4 dia. 7 8.2
E32-T17L
Sensing head (ABS) M14 x 1 10-mm dia. lens (PMMA) Two hexagon clamping nuts Optical fiber, 2.2 dia.
R3.5 10.5 7 8
Optical axis
Two, 3.2 dia.
Optical fiber, 2.2 dia.
19 2.5 10+0.2 9.2 16 11.2 2,000
5
23 42 10,000
E32-T12F
4-mm dia. lens Sensing head, 5 dia. Fluoride resin 4 dia. Optical fiber, 2.2 dia.
20 2,000 100
2 45
E3X
E32-M21
Sensing head M3 x 0.35 (SUS303) Two hexagon clamping nuts Two toothed washers Silicone tube
E3X
Note:
Plastic fibers, four, 1 dia.
One set of silicone tubes is black while the other set is gray for easy identification when they are connected to the light source and receiver.
Sleeve
13 28
1.8 11 23 2,000
E32-T51
1.5 dia. Two hexagon clamping nuts Two toothed washers Sensing head M4 x 0.7 (nickel-plated brass)
Note:
Resistant temperature is 150C. Resistant temperature is 130C when used continuously.
7
2.85 dia. 1
2.4 15 17
Optical fiber, 2.2 dia. 2,000
E32-T61
Two hexagon clamping nuts Two toothed washers 1.0 dia. M2.6 x 0.45 SUS flexible tube 2.8 dia. Sensing head M4 x 0.7 (SUS303) Hexagon clamping screw 4 dia. 5 dia. Sleeve
7
3 20
2.4
4 dia. 10 A 2,000 5 28 B
(See note) 13
Note:
Section A resists 300C and section B (which is inserted to the Amplifier) resists 110C. The operating temperature of section B must also be within the withstand temperature range of the Amplifier.
3 46
E3X
Reflective
E32-D11L
Two, 1.4 dia. 4 dia. Two hexagon clamping nuts Two toothed washers Sensing head (nickel-plated brass) M6 x 0.75 Two optical fiber, 2.2 dia.
E3X
5.2 10
3
20
2.4
2,000
E32-D12
2,000 (standard length) 3 dia. 15 135
Two, 1 dia. Sensing head (stainless) Heat-shrinkable tubing Optical fibers, two, 2.2 dia.
E32-D21L
Two, 0.9 dia.
Two hexagon clamping nuts Two toothed washers Sensing head M4 x 0.7 (nickel-plated brass) Optical fiber, two, 1 dia.
Two fiber attachments (E39-F9) 25 10
3.2 7
3 15
2.4 2,000 Two fiber attachments (E39-F9) 25 10 Optical fiber, two, 1 dia.
E32-D22L
Two, 0.9 dia. 2.7 dia. Sensing head 3 dia. (nickel-plated brass)
3 15 2,000
E32-DC200
Two, 1.0 dia. 4 dia.
Two hexagon clamping nuts Two toothed washers Sensing head M6 x 0.75 (ADC) Optical fiber, 2.2 dia. 3 4.8 10 2.4 17
2,000
E32-DC200B E32-DC200B4
Stainless Two hexagon clamping nuts Two, 1.0 dia. tube Two toothed washers (SUS304) Sensing head M6 x 0.75 (fine screw) 2.5 dia. max.
Note:
5.2 10
2.4 90 (40) (see note) 17
Optical fiber, 2.2 dia. 2,000
The value in the parentheses is for the E32-DC200B4.
E32-DC200E
Two, 0.5 dia. Two hexagon clamping nuts Two toothed washers Sensing head M3 x 0.5 (SUS304) Optical fiber, two, 1 dia.
Two fiber attachments (E39-F9) 25 10
2.5 5.5
1.8 11 2,000
4 47
E3X
E32-DC200F E32-DC200F4
Stainless tube Two, 0.5 dia. (SUS304) 1.2 dia. min. Two hexagon clamping nuts Two toothed washers Sensing head M3 x 0.5 (SUS304) Optical fiber, two, 1 dia. Fiber attachment (E39-F9) 25 10
E3X
2.5 5.5 90 (40) (see note)
1.8 11 2,000
Note:
The value in the parentheses is for the E32-TC200F4.
E32-D11
Sensing head Two hexagon clamping nuts (SUS303) Sixteen, Two toothed washers (10 teeth) 0.265 dia. M6 X 0.75 Protective tube Optical fiber, two, 2.2 dia.
2.4 5.2 10 17
15
2,000
E32-D21
Sensing head (nickel-plated brass) Two hexagon clamping nuts M3 x 0.5 Two toothed washers Four, 0.25 dia. Protective tube
Fiber attachment (E39-F9) 25 10 Optical fiber, two, 1 dia.
2.5 5.5
1.8 11
15 2,000
E32-DC200C
Two, 1.0 dia.
Two hexagon clamping nuts Two toothed washers Sensing head M6 x 0.75 (nickelplated brass)
(150)
22 dia. 2.4 17 Optical fiber, 2.2 x 2 dia. 90 2,000 (when straight)
5.2 10
400
E32-DC200D E32-DC200D4
Stainless Two, 1.0 dia. tube 2.5 dia. (SUS304) max.
Two hexagon clamping nuts Two toothed washers Sensing head M6 x 0.75 (SUS304)
(150)
Note:
The value in the parentheses is for the E32-DC200D4.
22 dia. Optical fiber, two, 2.2 dia. 90
2.4 5.2 10 90 17 (40) (see note)
2,000 (when straight) Sleeve
400
E32-DC9G E32-DC9G4
1.2 dia. max.
Stainless tube
4 8 15
Do not bent the stainless tube in this range. 10 90 (40) (see note) 17 7.5 13 6
Note:
The value in the parentheses is for the E32-TC200F4.
Fiber attachment (E39-F9) 25
E32-D33
Two, 0.25 dia. Sensing head (SUS303) 3 dia. 0.8 dia. Heat-shrinkable tubing Optical fiber, two, 1 dia.
10
15 35
15
12 2,000
5 48
E3X
E32-CC200
Sixteen, 0.25 dia. for light reception 1.0 dia. for light emission 2.5 dia. Two hexagon clamping nuts Two toothed washers Sensing head M6 x 0.75 Optical fiber, two, 2.2 dia. (nickel-plated brass)
E3X
5.2 10
3
2.4 23
2,000
Note:
The fiber for the light source is identified by a white line.
Two fiber attachments (E39-F9) 25
E32-D32
Light source fiber (0.5 dia.) Sensing head SUS303 Optical fibers, two, 1 dia. 2 dia. 3 dia. Heat-shrinkable tubing
10
Receive fiber (0.25 dia.) x 4
15 22
2
12 2,000
Note:
The fiber for the light source is identified by a white line.
E32-D32L
Light source (1 dia.) 15 400 2,000 (standard length) 15 1,570
Receive (0.265 dia.) x 16 Sensing head, 3 dia. (stainless) Branching box, 6 dia. (heat-resistive ABS black resin) Optical fibers, two, 2.2 dia.
Note:
The fiber for the light source is identified by a yellow dotted line.
Optical fiber, two, 2.2 dia. Heat-shrinkable tubing
E32-D14L
5.7 6 dia. 1.5 1 2
Sensing head (stainless) 45
Light baffle
30 35
12
2,000
Sensing surface
E32-D24
Sensing head (SUS304) 2 dia. 3 dia. 45% Heat-shrinkable tubing Optical fibers, two, 1 dia.
Two fiber attachments (E39-F9) 25 10
1 0.5
1.5 15 35
15
12 2,000
Light baffle
Sensing surface
E32-D12F
Sensing head, 6 dia. Fluoride resin 5 dia. Optical fiber, two, 2.2 dia.
16
2,000
100
6 49
E3X
E32-D51
Two, 1.5 dia. 4.9 2.4 3 13 17 2,000 Two hexagon clamping nuts Two toothed washers Optical fiber, 2.2 dia. Sensing head,M6 x 0.75*
E3X
*nickel-plated brass
Note:
3.1 10
Resistant temperature is 150C. Resistant temperature is 130C when used continuously.
E32-D61
1.4 dia. M4 x 0.7 Two hexagon clamping nuts Two toothed washers SUS304 Sensing head (SUS303) SUS flexible tube Hexagon clamping screw M3 x 0.75 5 dia. 3.5 dia. Sleeve
8
15
10
32
20
2.4
3 5
2,000 A
5
16.5
6.5 B
(See note) 13
6.4
Note:
Section A resists 300C and section B (which is inserted to the Amplifier) resists 110C. The operating temperature of section B must also be within the withstand temperature range of the Amplifier.
Two hexagon clamping nuts Two toothed washers M4 x 0.7 (SUS303) SUS flexible tube 4 dia. 2.8 dia.
E32-D73
Sensing head 2.5 dia. 1.25 dia. 1.65 dia. SUS303 Hexagon clamping screw 5 dia. Sleeve
1.0 dia.
8
15
7 5 60 5 A 2.4 20 10 2,000 B 5 16.5 6.5 C (See note) 13 6.4
Note:
Section A resists 400C, section B resists 300C, and section C (which is inserted to the Amplifier) resists 110C. The operating temperature of section C must also be within the withstand temperature range of the Amplifier.
Two fiber attachments (E39-F9) 25 10
E32-R21
Lens (PMMA) Two hexagon clamping nuts Two washers Sensing head Silicone tube M6 x 0.75 Optical fibers, two, 1 dia. 5 dia. 2.2 10 2.8 3 11 17.8 27.8 Nameplate 27 15 7 13 14 2,000
E32-R16
10 7.2
3.2 (6)
1.5 16
1.5 3.2 4
15.2 21.5
8
Lens (PMMA) 1
17
21 22.5
16+0.2
Optical fiber, two, 2.2 dia. Standard length: 2 m Two, M3 screws (attachment) Mounting bracket (attachment)
7 50
E3X
E32-L25
20 10 6.5 20 6.5 4.8 White line Optical fiber, two, 2.2 dia. Two, 3.2 dia., 6 dia. spot facing 2,000 White line 4 20
E3X
E32-L25A
5 4 20 10 4.8 6.5 5 6.5
Two, 3.2 dia., 6 dia. spot facing Sensing head (ABS)
2,000
Note:
The fiber for the light source is identified by a white line.
Optical fiber, two, 2.2 dia.
E32-L25L
4 6 16 6.5
18 25 Two, 1 dia. optical fibers 10
Two fiber attachment (E39-F9)
Sensing head (PC) Two, 3.2 dia, 6 dia. counter sinking
2,000
E32-L24L
4 3.6 3.3 3.3 1.5 Optical axis 6 Two, 1 dia. optical fibers 6.5 10 4 25 18 Side view prism (PC) Two fiber attachment (E39-F9)
20
Sensing head (PC) Two, 3.2 dia, 6 dia. counter sinking
2,000
8 51
E3X
Fine Through-beam
E32-T22S E32-T24S
17.6 0.4 1.8 Sensing head (nickel-plate brass) 3.5 dia. 11 3.2 Optical fiber 2.2 dia.
E3X
3
3.2 10 20.5 2 dia.
Mounting bracket (attachment) 2,000
2
Sensing surface
E32-T84S
2,000 (standard length) (see note)
4 dia.
2.9 dia. flexible tube (stainless)
4 dia.
5 dia.
Sleeve
3.5 dia. Sensing head (stainless) 3 dia. Lens (2 dia.)
Note:
Section A resists 200C and section B (which is inserted to the Amplifier) resists 110C. The operating temperature of section B must also be within the withstand temperature range of the Amplifier.
Slot Fiber Units
E32-G14
36.3 25.2 20 9.2 R1.6 R1.6 Two, M3 R3.5 Lens (PMMA) 4 23.5 1.6 9.4 1.6 Optical fiber, 2.2 dia. Sensing head (ABS) 2,000
Mounting Holes
24 10 Optical axis
3.2 9.0
9.4
7.4 7.0
9 52
E3X Liquid Level Fiber Units
E32-D82F1/E32-D82F2 (Liquid Contact Model)
6 dia. sensing head (Teflon) 9 dia. fiber connector (nickel-plate brass) Two, 2.2 dia. optical fiber (see note 2) To Amplifier Bending-prohibited length: 150 (350) (see note 1)
E3X
Note:
1. The value in the parentheses is for the E32-D82F2. 2. Since the 2-m optical fiber on the Amplifier side is made of plastic, the fiber is trimmable.
E32-L25T (Pipe Mounting Model)
Optical axis Two, 3.2 dia. lens (PC)
Two, fiber attachment Two, 1 dia. optical fiber
Mounting hole Sensing head (PC) 2,000 (standard length)
10 53
E3X
E32-T16
10.2 4 20 3.2 2 (R)
E3X
Mounting Holes
4 20 20 Sensing head (ABS) 3 8.4 1.2 2 (R) 2 (R) 4.5 Two, M3 5.5 3.2 11 2.3
0.5-mm Wide Silt Seal (Sold in Pairs)
6 0.5 4
15.5 8.85
15 23
Black 27 25 20
1-mm Wide Silt Seal (Sold in Pairs)
58 43.2 Two, 3.2 dia. 4 6 1
6 dia.
Lens (2 x 10) (PMMA)
2,000 Mounting bracket E39-L4 Black Fiber 2.2 dia. 33 15 23
E32-T16P
Two, 3.2 dia., 6 dia counter sinking 14.5 10.7
4
0.5-mm-wide Slit Seal (Sold in Pairs)
3.4 0.5
E32-T16P with E39-L94 Mounting
35 2 4 20 4.8
19
27 20 Sensing head (2 x 11) (PMMA) 13.4 26.4 Two, M3 4 20
4
Sensing head (heat-resistive ABS)
Black
12.2 3.2
1-mm-wide Slit Seal (Sold in Pairs)
2,000 3.4 1 2.2-dia. optical fiber 13.4 52 43.2 26.4 23.2 Black 2.2-dia. fiber E39-L94 Mounting Bracket 4 Sensing head 19
11 54
E3X Amplifier
E3X-T11 E3X-T21
17.8 Light reception indicator 9 Stable operation indicator 12 6.5 1.2 Tuning indicator 4
E3X
59
Two, 2.4
4.2
11
32 8 8.4 25 0.4 12.5 3.9 6 22.5 13 16 35.5 3.2 dia. Mounting bracket (removable) 6
Cord: 2-m polyvinyl chloride-covered cord (4-mm dia., 3 cores*) Weight: Approx. 100 g *The cords for the E3X-T21 model has 6 cores.
3.4 22.5
2 16
E3X-H11 E3X-Ajj E3X-Fjj E3X-VGjj
15.8
Light reception indicator
9
Stable operation indicator 59 Two, 2.4 dia. 4
8 8.4
30
25 12.5 3.9
6
Cord: 2-m polyvinyl chloride-covered cord (4-mm dia., 5 cores*) Weight: Approx. 100 g *The cords for the E3X-A11, E3X-A41, and E3X-VG11 models have 3 cores.
22.5 13
16 35.5
6 Mounting bracket (removable) 3.2 dia.
3.4 22.5
2 16
12 55
E3X Reflector
Reflector (Small) E39-R3
11 Adhesive tape Two, 3.5 dia. 7 20
E3X
Reflector E39-R1
40.3 34 7.5
Note:
Mounting bracket is attached.
0.2
59.9 52
34.8
25.4 34 38
8 1.6 2.7
19.3 Two, M3 2.6
1.2
Attachments
E39-F1 Lens Kit
M2.6 x 0.45 Effective depth: 3.8 Spot facing depth: 0.9 4 dia. 8.9 4 dia. 5.7 9.2 6.4 8+0.2 6.5 20.7 18 6.4 12
E39-F2 Side-view Attachment
2.8 dia. M2.6 Effective depth: 3.2 Spot facing depth: 0.9
E39-F3 Convergent Beam Conversion Kit
Two, 4 dia. M3 toothed washers Two, 3.2 +0.2 dia. 0 Two, M3 x 3 Slotted head machine screw
Note:
One set includes two units.
3 3.6 8.5
M3 x 6 Angle fixing screw
E39-F5 Side-view Diffuse Reflective Conversion Kit (for the E32-TC200A)
Sensing hole Two, 3.2 dia. 12.2 Two, M3 Fiber unit mounting Two, 3.2 dia. holes (E32-TC200A) Mounting hole 2.1 4 13 2.6 4 10.5+0.1 18 5
E39-F3A Reflective Lens Unit (for the E32-D32)
4 dia. 6 dia. Lens (3.7 dia.) 23
M2 x 2
3 13 2.1 dia.
56 13
E3X Protective Spiral Tubes
E39-F32A, E39-F32A5 E39-F32B, E39-F32B5
M3 x 0.5 depth: 4 6 dia. 12 L 12 Head connector 4.6 dia. End cap 3 dia.
E3X
Note:
1. L is as follows: E39-F32A and E39-F32B: 1,000 E39-F32A5, E39-F32B5: 500 2. A pair of E39-F32A(5)'s is sold as E39-F32B(5).
Head connector 5.6 dia. End cap 4 dia.
E39-F32C, E39-F32C5
M4 x 0.7 depth: 4 7 dia. 12 L 12
Note:
L is as follows: E39-F32C: 1,000 E39-F32C5: 500
Head connector 7 dia. End cap 5 dia.
E39-F32D, E39-F32D5
M6 x 0.75 depth: 4 8.5 dia.
12 L
12
Note:
L is as follows: E39-F32D: 1,000 E39-F32D5: 500
Accessories
E39-F4 Fiber Cutter
Holes for standard fiber
Holes for thin fiber
E39-F9 Attachment for Thin Fiber
E39-F10 Fiber Connector
1.1 dia.
Insertion mark (2.4 dia.) 10 11.7 25
Retention clip
Splice
Retention clip Fiber
3.6 dia.
3.8 dia.
26
3 dia.
12.8
2.2 dia.
Note:
One set includes two Units.
14 57
E3X
E39-G3 Manual Sensitivity Adjustment Knob
Note: Cannot be used with the E3X-Tjj.
E3X
10 dia.
E39-G4 Protective Cover
Note: Cannot be used with the E3X-Tjj.
15 58
E3X
E3X
Installation
Connections
Connection with S3D2 Sensor Controller
Blue Black Brown +12 V 7 10 IN1 NORM 4 5 1 2 8 11 9 12 IN2 INV 6 3 0V
Connection with S3D8 Sensor Controller
Black Blue 0 V Brown +12 V IN1
Note:
A maximum of two E3X Optical Fiber Photoelectric Sensors can be connected. Output Relay AND, OR
Note:
A maximum of eight E3X Optical Fiber Photoelectric Sensors can be connected. NPN input S3D2-AK-US S3D2-CK-US S3D2-BK-US S3D2-CC-US PNP input S3D2-AKB-US S3D2-CKB-US --S3D2-CCB-US
Power supply voltage 100 to 240 VAC
Functions AND, OR, and timer Flip-flop
Transistor
AND, OR, and timer
16 59
E3X
E3X
Precautions
Fiber Units
Tightening Force
The tightening force applied to the Fiber Unit should be as follows: Screw-mounting Model
Spring mounting clip Toothed washers
Fiber Connection and Disconnection
The E3X Amplifier has a push lock. Connect or disconnect the fibers to or from the E3X Amplifier using the following procedures: 1. Connection
Nuts (attachment)
Column Model
Retaining screw (M 3 max.) Clamping torque 3 kgf S cm max.
Insert the fibers into the E3X Amplifier and press the push lock until the Amplifier clicks to lock the fibers. The fibers will have insertion marks when they are cut with the E39-F4 (Fiber Cutter). The portion from the tips to the insertion mark should be inserted to the E3X. 2. Disconnection Be sure to press the push lock again to unlock before pulling out the fiber, otherwise the fiber may be deteriorated.
Fiber Insertion
If the portion from the tip to the insertion mark of the fibers are not inserted into the Amplifier Unit, the sensing distance will be reduced. Fiber units M3/M4 screw M6 screw 2-mm dia. column 3-mm dia. column E32-D14L E32-T12F E32-D12F E32-T16 E32-R21 E32-M21 Clamping torque 8 kgf S cm max. (0.78 N S m) 10 kgf S cm max. (0.98 N S m) 3 kgf S cm max. (0.29 N S m) 3 kgf S cm max. (0.29 N S m) 10 kgf S cm max. (0.98 N S m) 8 kgf S cm max. (0.78 N S m) 8 kgf S cm max. (0.78 N S m) 5 kgf S cm max. (0.49 N S m) 6 kgf S cm max. (0.59 N S m) Up to 5 mm to the tip: 5 kgf S cm max. (0.49 N S m) Up to 5 mm from the tip: 8 kgf S cm max. (0.78 N S m) 8 kgf S cm max. (0.78 N S m)
Fiber unit 12.6 mm
2.2-mm dia. Fiber
Insertion mark
Amplifier
Thin Fiber with the E39-F4 Attachment
The portion from the tips to the insertion mark should be inserted into the E3X. Amplifier
Fiber unit 12.6 mm
E32-L25A
Use a proper-sized wrench.
Fiber with Fixed Length
The portion from the tips to the insertion mark should be inserted into the E3X. Amplifier
12.6 mm
17 60
E3X
Cutting Fiber
Insert a fiber into the Fiber Cutter and determine the length of the fiber to be cut. Press down the Fiber Cutter in a single stroke to cut the fiber. When the fiber is cut, an insertion mark is inscribed on the fiber. For a 2.2-mm dia. standard fiber only.
40 mm max. 12.6 Insertion mark
E3X
Connection
Do not pull or press the Fiber Units. The Fiber Units have a withstand force of 1 kg or 3 kg (pay utmost attention because the fibers are thin). Do not bend the Fiber Units beyond the permissible bending radius. Do not bend the edge of the Fiber Units.
Correct
Amplifier 2.2-dia. Fiber unit
Insert a fiber into the Fiber Cutter in the direction indicated by the arrow (refer to the following figure).
2
20 mm max.
Incorrect
Do not apply excess force on the Fiber Units.
1 Fiber unit Fiber unit
The cutting holes cannot be used twice. If the same hole is used twice, the cutting face of the fiber will be rough and the sensing distance will be reduced. Always use an unused hole. Use either one of the two holes on the right (refer to the following figure) to cut a thin fiber as follows: 1. An attachment is temporarily fitted to a thin fiber before shipment.
Nylon wireholder
Correct
Metal holder
Incorrect
The Fiber Head could be broken by excessive vibration. To prevent this, the following is effective:
Temporarily fitted
2. Secure the attachment after adjusting the position of it in the direction indicated by the arrow. 3. Insert the fiber into the E39-F4 to cut.
A A one-turn loop can one-turn loop can absorb vibrations. absorb vibrations
Tape Cutter E39-F4 Two holes for thin fiber Three holes for standard fiber (2.2 mm dia.)
Note:
Insert the fiber in the direction indicated by the arrow.
18 61
E3X
Bending Radius
E39-F11 Sleeve Bender The bending radius of the stainless tube should be as large as possible. The smaller the bending radius becomes, the shorter the sensing distance will be. Insert the tip of the stainless sleeve to the Sleeve Bender and bend the stainless sleeve slowly along the curve of the Sleeve Bender (refer to the figure).
1.2 dia. 1.2 dia. 1.3 dia. max. max. min. R 10 R 12.5 R 7.5 Fiber tip position mark Seal R5
E3X
Handling
E32-D51/-T51 Heat-resisting Fiber The bending radius of the fibers should be 35 mm min. Connecting fibers via the E39-F10 Fiber Connector is not possible. The withstand temperature of the Heat-Resisting Fibers is 150C max. In continuous operation, the ambient temperature should be 130C max. E32-T14/-T51 If the sensor is ON because some object in front of the lenses reflects light, attach the black seals (sold together) to the lenses. E32-T14/-G14
Stainless tube
E32-L25 (A) Wafer Sensor Insert the fiber with a white line into the light projection side of the Amplifier. The tightening force of the sensor head is 8 kgf S cm (0.75 N S m). Avoid places where water could be sprayed onto the E32-L25(A). E32-T16 Slit Seal (Attachment) Peel the E32-T16 Slit Seal off the ground paper and affix the Slit Seal to the sensing face of the sensor so that the corners of the Slit Seal fit in with the corners of the sensing face. To sense an object at a distance of 30 cm max., a 0.5-mm wide Slit Seal must be used.
90o max.
10
10 Do not bend here.
E32-T16 Sensing Head
Attachment slit
Amplifier Units
Mounting
Mounting 1. Mount the front part on the mounting bracket (sold together) or a DIN rail. 2. Press the back part onto the mounting bracket or the DIN rail.
3
Others When power is off: The moment power is turned off, the E3X could output a pulse signal which could affect the operation of the devices connected to it. This will happen more often if power is supplied to the E3X from an external power supply, thus affecting the connected timer and counter. Use a built-in power supply as much as possible to avoid this. If power is supplied to a photoelectric sensor through a cord that is wired together with other power lines in the same duct, the cord will be influenced by the power lines and malfunctioning of the photoelectric sensor or damage could result. Wire the cord separately or use a sealed cord to supply power to the photoelectric sensor. In the case of the cord is extended, use a wire with 0.3 mm2 max.. The total length of the cord should be 100 m max.
2 1 DIN rail Power lineline Power
Dismounting By pulling back the lock (yellow) on the bottom with a flat blade screwdriver, the Amplifier can be dismounted with ease. In the case of side mounting, attach the mounting bracket on the Amplifier first, and secure the Amplifier with M3 screws and washers. The diameter of the washers should be 6 mm max.
Washers (6 dia. max.)
Power supply: If a standard switching regulator is used as a power supply, the frame ground (FG) terminal and the ground (G) terminal must be grounded, or otherwise the E3X can malfunction, influenced by the switching noise of the power supply. The supplied voltage must be within the rated voltage range. Unregulated full- or half-wave rectifiers must not be used as power supplies. Do not use a hammer to hit the Amplifier when mounting or the Amplifier will loose watertightness.
19 62
E3X Attachment Units
Applications
E39-F10 Fiber Connector Use the following procedure (refer to the figure) to connect fibers via the Fiber Connector.
Splice Retention Unit Retention Unit
E3X
E39-F3A Reflective Unit Lens When the E39-F3A is attached to the fiber, the E3X can sense the light reflected from the interior of the E39-F3A. If this happens, adjust the sensitivity of the E3X Amplifier with Sensitivity Adjustor. Place a sensing object or white paper at the sensing distance set and adjust the insertion length of the Fiber Unit to the E39-F3A so that the light spot is as small as possible. Then fix the position of the Fiber Unit with the hexagonal wrench (attachment)
Tighten
Loosen
A Lens
Each fiber should be as close as possible before they are connected. Sensing distance will be reduced by approximately 25% when fibers are connected. Only fibers with 2.2 mm dia. can be connected. Protective Spiral Tube Insert a fiber to the Protective Spiral Tube from the head connector side (screwed) of the tube.
B Insertion Fiber Unit (E32-D32)
A: The focus is farther than the E39-F3A. B: The focus is closer than the E39-F3A
E39-G3 Sensitivity Adjustor
1. Remove the cover of the E3X. 2. Attach the E39-G3 (refer to the figure).
Protective spiral tube
Fiber Unit Knob
Cover
Push the fiber into the Protective Spiral Tube. The tube should be straight so that the fiber is not twisted when inserted. Then turn the end cap of the spiral tube.
Protective spiral tube
Fiber Unit
Secure the Protective Spiral Tube on a suitable place with the attached nut.
Mounting panel Hexagon clamping nut
3. After the cover is attached to the case, turn the knob of the E39-F3A clockwise or counterclockwise once. To confirm that the knob has been set properly, turn the knob clockwise or counterclockwise until you hear a click (8 turns max. are necessary). Note: E3X looses watertightness if E39-G3 is attached (the enclosure rating will be IP50).
Fiber Unit Protective spiral tube Toothed washer
Use the attached saddle to secure the end cap of the Protective Spiral Tube. To secure the Protective Spiral Tube at a position other than the end cap, apply tape to the tube so that the portion becomes thicker in diameter.
Saddle Tube
End cap
20 63
E3X
E3X
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. E215-E1-3
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Systems Components Division H.Q. 28F Crystal Tower Bldg. 1-2-27, Shiromi, Chuo-ku, Osaka 540 Japan Phone: 06-949-6012 Fax: 06-949-6021 Printed in Japan 0196-2M (0691) a
21 64


▲Up To Search▲   

 
Price & Availability of E32-TC200D4

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X